Table 29. Clustered Ethernet host connections for OpenStorage configuration, Feature Code 3457
Callout
From
On Device
To
On Device/Location
13
Slot 3, port 1
Server A
Designated device
Customer host network
14
Slot 3, port 2
Server A
Designated device
Customer host network
15
Slot 4, port 1
Server A
Designated device
Customer host network
16
Slot 4, port 2
Server A
Designated device
Customer host network
17
Slot 3, port 1
Server B
Designated device
Customer host network
18
Slot 3, port 2
Server B
Designated device
Customer host network
19
Slot 4, port 1
Server B
Designated device
Customer host network
20
Slot 4, port 2
Server B
Designated device
Customer host network
Procedure
Perform the following steps to verify OpenStorage Fibre Channel connections.
1.
Use Figure 38 on page 65 and Table 28 on page 66 to verify the Fibre Channel
connections made in manufacturing.
2.
Connect the Fibre Channel cables to the customer host network according to
Figure 39 and Table 29.
Note:
The customer must use an additional connectivity device between the
optical Fibre directly connected to RMSS optical adapters (for example, Fibre,
ESCON, or FICON) and an external public network. It can be a patch panel,
router, switch, or other suitable device. Optical Fibre connectivity that does not
go over a public network does not require an additional connectivity device.
ts760867
1
1
2
2
1 2 3 4 5 6
7
E1
E2
1
3
2
4
P1
P2
8
A1 A2
9
B
V
E3
E4
S
1
2
1
2
ProtecTIER Server B
1
1
2
2
1 2 3 4 5 6
7
E1
E2
1
3
2
4
P1
P2
8
A1 A2
9
B
V
E3
E4
S
1
2
1
2
18
14
17
19 20
13
15 16
ProtecTIER Server A
Figure 39. Clustered customer host network Ethernet connections for OpenStorage
configuration, Feature Code 3457
Chapter 3. Installing the appliance
67
Summary of Contents for TS7650 PROTECTIER DEDUPLICATION APPLIANCE
Page 8: ...viii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 12: ...xii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 14: ...xiv IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 18: ...xviii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 26: ...xxvi IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 126: ...100 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 152: ...126 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 162: ...136 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 164: ...138 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 194: ...168 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 206: ...180 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 214: ...188 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 217: ......
Page 218: ...Part Number 95P8310 Printed in USA or Mexico GA32 0920 02 1P P N 95P8310...