Operating
environment
Nonoperating
environment
Storing
environment
Shipping
environment
Altitude
(from
sea
level)
0
to
2000
m
(0
to
6560
ft.)
0
to
2000
m
(0
to
6560
ft.)
0
to
2000
m
(0
to
6560
ft.)
0
to
15
000
m
(0
to
49
212
ft.)
Heat
output
(maximum):
142
watts
(485
Btu
per
hour)
during
normal
operation.
553
watts
(1887
Btu
per
hour)
when
power
has
failed
and
the
uninterruptible
power
supply
is
supplying
power
to
the
nodes
of
the
SAN
Volume
Controller.
Related
topics:
v
Preparing
your
master
console
environment
This
topic
provides
information
you
need
to
ensure
that
your
physical
site
meets
the
installation
requirements
for
the
master
console
server
and
console
monitor
kit.
Server
dimensions
and
weight:
Height
Width
Depth
Approximate
Maximum
Weight
43
mm
(1.7
in.)
430
mm
(16.69
in.)
424
mm
(16.54
in.)
12.7
kg
(28
lb.)
(depending
on
your
configuration.)
Note:
The
above
dimensions
are
for
a
1U
monitor
and
keyboard
assembly.
Server
acoustical
noise
emissions:
Sound
power,
idling
Sound
power,
operating
6.5
BEL
maximum
6.5
BEL
maximum
Server
AC
and
input-voltage
requirements:
Power
Supply
Electrical
input
203
watt
(110
or
220
V
ac
auto-sensing)
Sine-wave
input
(47–63
Hz)
required
Input
voltage
low
range:
Minimum:
100
V
ac
Maximum:
127
V
ac
Input
voltage
high
range:
Minimum:
200
V
ac
Maximum:
240
V
ac
Input
kilovolt-amperes
(kVA),
approximately:
Minimum:
0.0870
kVA
Maximum:
0.150
kVA
Appendix.
Preparing
your
SAN
Volume
Controller
environment
49
|
|
Summary of Contents for TotalStorage
Page 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 2: ......
Page 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 1 2 0 SC26 7541 02...
Page 22: ...xx Installation Guide...
Page 36: ...14 Installation Guide...
Page 58: ...36 Installation Guide...
Page 74: ...52 Installation Guide...
Page 80: ...58 Installation Guide...
Page 84: ...62 Installation Guide...
Page 89: ......
Page 90: ...Part Number 64P8120 Printed in USA SC26 7541 02 1P P N 64P8120...
Page 91: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 1 2 0...