2. Using Figure 42 as a guide and use the following steps to remove the failed fan
and communications module from the FAStT700 Storage Server.
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
OU
T
IN
!
2 G
b/s
1 G
b/s
a. Using a flat-blade screwdriver, loosen the two captive screws on the fan and
communications module.
b. Use the pull handle to slide the module out of the slot a few inches.
c. Grasp the sides of the module with both hands and remove it from the
FAStT700 Storage Server.
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling static-sensitive
devices, see “Handling static-sensitive devices” on page 35.
3. Unpack the new fan and communications module.
4. To install the new fan and communications module do the following:
a. Push the new fan and communications module all the way into its chassis
slot.
b. Use a flat-blade screwdriver to tighten the two captive screws on the new
module, securing it into place.
5. Check the fan and communications indicator light. See Figure 41 for the location
of the fan and communications indicator light.
v
If the amber fault indicator light is on, make sure that the fan and
communications module is inserted all the way into the chassis and secured
in place.
v
If the fault indicator light remains on, one or both fans inside the fan and
communications module might be malfunctioning. Replace the failed fan and
communications module with a spare, if available. Otherwise, shut down the
FAStT700 Storage Server until you can replace the failed fan and
communications module with a new one.
6. Reconnect the interface cables that you disconnected in Step 1 on page 47 to
the new fan and communications module.
Figure 41. Fan and communications module ports and indicator light
Figure 42. Removing and installing a fan and communications module
48
IBM
®
TotalStorage
™
FAStT700 Fibre Channel Storage Server: User’s Guide
Summary of Contents for TotalStorage FAStT700
Page 1: ...IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 2: ......
Page 3: ...IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 8: ...vi IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 10: ...viii IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 16: ...xiv IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 96: ...78 IBM TotalStorage FAStT700 Fibre Channel Storage Server User s Guide...
Page 99: ......