FAStT100
specifications
lists
the
specifications
for
the
FAStT100.
Table
8.
IBM
TotalStorage
FAStT100
specifications
Size
v
Width
:
48.1
cm
(18.97
in.)
v
Height
:
13.2
cm
(5.21
in.)
v
Depth
:
59.7
cm
(23.52
in.)
Weight
v
Drive-ready
weight
(without
disk
drive
modules
installed):
26.5
kg
(58.3
lb)
v
Fully
configured
weight
(with
14
disk
drives
installed):
40.8
kg
(85.7
lb)
Electrical
input
v
Sine-wave
input
(50
-
60
Hz)
is
required
v
Input
voltage
low
range:
–
Minimum:
90
V
ac
–
Maximum:
127
V
ac
v
Input
voltage
high
range:
–
Minimum:
198
V
ac
–
Maximum:
257
V
ac
v
Input
kilovolt-amperes
(kVA),
approximately:
–
Minimum
configuration:
0.06
kVA
–
Maximum
configuration:
0.39
kVA
Environment
v
Air
temperature
–
Operating:
-
Altitude:
0
-
914
m
(3000
ft):
10°
-
35°
C
(50°
-
95°
F)
-
Altitude:
914
m
-
2133
m
(3000
-
7000
ft):
10°
-
32°
C
(50°
-
90°
F)
Important:
The
recommended
operating
environment
air
temperature
is
22°
C
(72°
F)
or
lower.
–
Storage:
-
Altitude:
0
-
914
m
(3000
ft):
1°
-
60°
C
(33°
-
140°
F)
v
Humidity
–
8%
-
80%
–
Noncondensing
Heat
dissipation
v
Fully
configured
storage
server
(14
1.5
Gbps
SATA
hard
disk
drives)
–
1088
BTU
per
hour
Acoustical
noise
emission
values
For
open
bay
(0
drives
installed)
and
typical
system
configurations
(eight
hard
disk
drives
installed):
v
Sound
power
(idling):
–
5.9
bel
(open
bay)
–
6.1
bel
(typical)
v
Sound
power
(operating):
–
5.9
bel
(open
bay)
–
6.2
bel
(typical)
v
Sound
pressure
(idling):
–
44
dBA
(open
bay)
–
46
dBA
(typical)
v
Sound
pressure
(operating):
–
44
dBA
(open
bay)
–
47
dBA
(typical)
These
levels
are
measured
in
controlled
acoustical
environments
according
to
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
The
declared
sound
power
levels
indicate
an
upper
limit,
below
which
a
large
portion
of
machines
operate.
Sound
pressure
levels
in
your
location
might
exceed
the
average
1-meter
values
stated
because
of
room
reflections
and
other
nearby
noise.
Notes:
1.
The
nonoperating
environment
must
not
exceed
the
operating
environment
limits
for
longer
than
60
days.
2.
The
storage
environment
must
not
exceed
the
operating
environment
limits
for
longer
than
1
year.
10
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...