3.
Install
the
new
fan
unit:
a.
Place
the
fan
CRU
in
front
of
the
fan
bay.
b.
Ensure
that
you
move
the
fan
latch
towards
the
exterior
of
the
storage
expansion
enclosure
(away
from
the
power
supply
and
ESM
CRUs)
before
you
insert
the
fan.
Hold
the
latch
in
the
open
position
while
inserting
the
fan
unit
into
the
fan
bay.
c.
Ensure
that
you
move
the
latch
in
the
same
direction
as
the
arrow
before
you
slide
the
fan
all
the
way
into
the
bay.
The
open
side
of
the
fan
CRU
faces
the
power
supply
and
ESM
CRUs.
If
the
fan
does
not
go
into
the
bay,
rotate
it
180°.
(See
d.
If
the
latch
does
not
automatically
lock
when
you
have
successfully
inserted
the
fan
unit
into
the
bay,
pull
back
on
the
fan
slightly,
and
then
push
it
in
again
until
the
latch
snaps
into
place.
4.
Check
the
LEDs.
The
Fault
LEDs
should
no
longer
be
lit
after
a
few
seconds;
if
they
remain
on,
see
2 G
b/s
X1
0
X1
Tra
y N
um
be
r
Conflict
1 G
b/s
e
xp70008
Figure
58.
Replacing
a
hot-swap
cooling
fan
Chapter
3.
Installing
and
replacing
devices
75
Summary of Contents for TotalStorage FAStT EXP700
Page 2: ......
Page 157: ......