background image

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb

/s

1 Gb

/s

OUT

IN

!

2 Gb

/s

1 Gb

/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb/s
1 Gb/s

OUT

IN

!

2 Gb

/s

1 Gb

/s

OUT

IN

!

2 Gb/s
1 Gb/s

Host 1, Host Adapter 1 and 2

Host 4, Host Adapter 1 and 2

Host 2, Host Adapter 1 and 2

Host 3, Host Adapter 1 and 2

Host 1

Host 4

Host 2

Host 3

For

 

additional

 

information

 

about

 

host-side

 

cabling,

 

refer

 

to

 

the

 

IBM

 

TotalStorage

 

DS4500

 

Fibre

 

Channel

 

Storage

 

Subsystem

 

Installation,

 

User's,

 

and

 

Maintenance

 

Guide

.

 

Drive-side

 

fibre-channel

 

cabling

 

The

 

DS4500

 

Storage

 

Subsystem

 

supports

 

up

 

to

 

two

 

redundant

 

drive

 

loops.

 

A

 

redundant

 

drive

 

loop

 

consists

 

of

 

one

 

or

 

more

 

storage

 

expansion

 

enclosures

 

connected

 

to

 

a

 

controller

 

using

 

two

 

sets

 

of

 

fibre

 

channel

 

cables.

 

If

 

one

 

data

 

path

 

fails,

 

the

 

controller

 

uses

 

the

 

other

 

data

 

path

 

to

 

maintain

 

the

 

connection

 

to

 

the

 

drive

 

group.

 

Figure

 

3.

 

DS4500

 

Storage

 

Subsystem

 

host

 

adapter

 

connections

 

(direct-attached)

 

5

Summary of Contents for TotalStorage DS4500

Page 1: ...ad All drives in the connected storage expansion enclosure s must contain no prior configuration data Table 1 Installation Tasks Task Detailed Description 1 Review the DS4500 installation recommendati...

Page 2: ...t FC HBAs Chapter 3 Connecting hosts to the DS4500 11 Connect the power cables for the DS4500 and the storage expansion enclosures if needed Chapter 3 Cabling the power supply 12 Power on the attached...

Page 3: ...Attention Remove SFP modules from any unused mini hub ports both host side and drive side on the DS4500 Storage Subsystem To avoid damage to your fibre optic cables v Do not route the cable along a f...

Page 4: ...closures in the rack cabinet before cabling the configuration OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb s 1 Gb s OUT IN 2 Gb...

Page 5: ...cabling refer to the IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide Drive side fibre channel cabling The DS4500 Storage Subsystem supports up to two...

Page 6: ...y FAStT EXP500 storage expansion enclosures the DS4500 Storage Subsystem supports a maximum of 220 hard drives Important Ensure that the single digit x1 of the enclosure ID for every enclosure in a re...

Page 7: ...left ESM board of the second enclosure Connect the In port on the right ESM board of the first enclosure to the Out port on the right ESM board of the second enclosure If you want to connect addition...

Page 8: ...ng with the second storage expansion enclosure connect each additional storage expansion enclosure into drive loops A and B in the same manner Leave port 1A on the ESM B board on the last storage expa...

Page 9: ...cupied The EXP810 enclosure IDs will automatically set to give each enclosure in the drive loop a unique enclosure ID EXP810 ESM B ESM A EXP810 ESM B ESM A EXP810 ESM B ESM A EXP810 ESM B ESM A Port 1...

Page 10: ...This page left intentionally blank 10...

Page 11: ...This page left intentionally blank 11...

Page 12: ...torage Other company product or service names may be trademarks or service marks of others Second edition October 2006 Copyright International Business Machines Corporation 2006 All rights reserved US...

Reviews: