background image

4. Optional step: If desired, install the right rack mount bracket

2

and the left

rack mount bracket

3

on the switch chassis. These brackets secure the switch

to the rack as shown in Figure 8.

a. Position the left rack mount bracket at the left front corner of the switch

chassis, so that the two holes in the bracket align with the two threaded
holes in the switch chassis.

b. Attach the bracket using two of the 8-32 x 3/16 in. zinc screws

6

.

Attention:

Using screws longer than 3/16 in. can damage the switch.

c. Repeat steps 4a 4b for the right rack mount bracket on the right front

corner of the switch chassis.

5. Attach all four of the 3-hole rack mounting brackets

4

as shown in Figure 9 on

page 14.

Sj000348

Front

1

6

3

Offset holes for

9306 Netfinity racks

Figure 8. Mounting the moving portion of the slide and the mounting brackets to the switch

Chapter 3. Installing and configuring the 3534 Model F08

13

Summary of Contents for TotalStorage 3534-F08

Page 1: ...F08 Installation Guide SY27 7631 00 Read Before Using The IBM License Agreement for Machine Code is included in this book Carefully read the agreement By using this product you agree to abide by the t...

Page 2: ......

Page 3: ...IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide SY27 7631 00...

Page 4: ...fety and environmental notices on page ix and Notices on page 39 First Edition May 2002 Copyright International Business Machines Corporation 2002 All rights reserved US Government Users Restricted Ri...

Page 5: ...odel F08 1 System components 2 Front panel 2 Back panel 2 Managing the 3534 Model F08 3 Chapter 2 Planning the installation 5 Chapter 3 Installing and configuring the 3534 Model F08 9 Installation and...

Page 6: ...ppendix B Blank planning worksheets 33 Planning worksheet 34 Port configuration worksheet 35 Zone definition worksheet 36 Zone configuration worksheet 37 Notices 39 Trademarks 40 Electronic emission n...

Page 7: ...4 Model F08 2 6 Back panel of the 3534 Model F08 3 7 Moving slide 12 8 Mounting the moving portion of the slide and the mounting brackets to the switch 13 9 Mounting the fixed portion of the rail and...

Page 8: ...vi IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 9: ...1 7 Configuration parameters 16 8 Front panel LED patterns during normal operation 20 9 Back panel LED patterns during normal operation 22 10 General specifications 28 11 Physical specifications 29 12...

Page 10: ...viii IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 11: ...voltage on metal parts of the system or the products that attach to the system It is the customer s responsibility to ensure that the outlet is correctly wired and grounded to prevent an electrical sh...

Page 12: ...find Checking the safety labels Perform the following safety label checks 1 Verify that the power supply cover caution label shown in Figure 1 is installed on the power supply of the 3534 Model F08 C...

Page 13: ...003 Class Classe A P N 18P4393 This device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device m...

Page 14: ...he transceiver complies with IEC 825 1 and FDA 21 CFR 1040 10 and 1040 11 The transceiver must be operated under the recommended operating conditions This equipment contains Class 1 laser products and...

Page 15: ...Product disposal This unit might contain batteries Remove and discard these batteries or recycle them according to local regulations Safety and environmental notices xiii...

Page 16: ...xiv IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 17: ...AN Fibre Channel Switch 3534 Model F08 User s Guide GC26 7454 v IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Command Reference GC26 7455 v IBM TotalStorage SAN Fibre Channel Switch 3534 Mo...

Page 18: ...is important to help us provide the highest quality of information If you have any comments about this book you can submit them in one of the following ways v E mail Submit your comments electronicall...

Page 19: ...figuring Capable of individually becoming a fabric enabled port F_port a fabric loop enabled port FL_port or an expansion port E_port v One serial port with an RS 232 connector v One 10 Mbps or 100 Mb...

Page 20: ...h link ISL Trunking group Note ISL Trunking enables traffic to be distributed over the combined bandwidth of up to four ISLs between two adjacent switches while preserving in order delivery It is mana...

Page 21: ...hat are compatible with the 3534 Model F08 and whether those interfaces can be used in band out of band or both Table 1 Management interfaces compatible with the 3534 Model F08 Management interface In...

Page 22: ...ense may be required For more information about these applications see the IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 User s Guide 4 IBM TotalStorage SAN Fibre Channel Switch 3534 Model...

Page 23: ...ion Firmware level V 3 1 0 Firmware location Server name C02STOR01 Username sanman Directory G sanman 3534 firmware v3 1 Switch name 3534SW1 Domain ID 1 FCnetID Fibre channel IP address FC netmask WWN...

Page 24: ...dentifies this switch in the SAN configuration FCnetID The fibre channel IP address for this switch FC netmask The netmask for the fibre channel IP network WWN The worldwide name of the switch that is...

Page 25: ...SW 204 5 Open 2 m 6 ft SW 205 6 s1411201e0 P2 I3 25 m 82 ft SW 206 7 s1411203e0 P2 I3 25 m 82 ft SW 207 Table 4 shows an example of a completed zone definition worksheet Table 4 Example of a complete...

Page 26: ...Port ID P 1 3 Same 2108 1 PMC1 1 Port ID P 1 4 Same 2108 2 PMC2 2 Port ID P 1 5 Same 2108 2 PMC3 3 Port ID P 1 6 Same s1411201e0 P2 I3 Port ID P 1 7 Same s1411203e0 P2 I3 Port ID P 15 0 Same 2108 1 PM...

Page 27: ...line to line connection greater than 200 V ac a potential shock hazard can arise during a fault condition Therefore double pole protection is required 5 v Ensure the ambient air temperature does not e...

Page 28: ...et The power supply does not have an ac switch The 3534 Model F08 automatically runs a POST each time power is supplied to it DANGER An electrical outlet that is not correctly wired could place a haza...

Page 29: ...s released usually referred to as the service aisle This prevents the fans from pulling in heated exhaust air Basic procedure The basic rack mount installation procedure consists of the following four...

Page 30: ...he 9306 Netfinity racks you can eliminate the installation of the ears Instead use the rack mount slides by attaching the 3534 Model F08 to the set of mounting holes which are offset 2 62 cm 3 in into...

Page 31: ...he switch chassis b Attach the bracket using two of the 8 32 x 3 16 in zinc screws 6 Attention Using screws longer than 3 16 in can damage the switch c Repeat steps 4a 4b for the right rack mount brac...

Page 32: ...At the desired height install the five M5 nut clips 5 put three in the front of the rack and two in the back The middle clip in the front of the rack is for the locking ears b Attach the slides using...

Page 33: ...o supply power to the switch connect the power cable to the 3534 Model F08 power supply and to a power outlet The power supply does not have an ac switch The 3534 Model F08 automatically runs a POST e...

Page 34: ...32 serial port on the workstation If no RS 232 serial port is available on the workstation the adapter on the end of the serial cable can be removed This enables you to use the RJ 45 connector to crea...

Page 35: ...ation using an Ethernet cable this can be a direct connection or through a network and to access the switch 1 Remove the shipping plug from the Ethernet port 2 Insert one end of an Ethernet cable in t...

Page 36: ...clicking sound Note The SFP is keyed so that it can only be correctly inserted into the port If the module does not slide in easily try turning it over Do not force the module c Connect the fiber opti...

Page 37: ...ng diagnostic tests and green orange or yellow during a POST This is normal and does not indicate a problem unless the LEDs do not return to a normal pattern after the POST is complete The 3534 Model...

Page 38: ...her the switch is off the startup process is not complete or the startup has failed Verify that the switch has power and that the startup process has had time to complete If there is still no light co...

Page 39: ...s disabled as a result of diagnostics or a portDisable command Reset the port from a management station Fast flashing orange on 1 4 second off 1 4 second The port is faulty Reset the switch from a man...

Page 40: ...n page 20 Slow flashing yellow A diagnostic failure has occurred on one or more ports Errors might be listed in the error log Refer to the IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 User...

Page 41: ...34 Model F08 User s Guide Note When POST completes verify that the switch prompt displays on a computer terminal that is connected to the switch If the prompt does not display press the Enter key If t...

Page 42: ...24 IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 43: ...install an SFP You do not need to unplug the switch to replace an SFP Figure 13 shows an IBM SFP Time required Approximately 20 seconds to remove and install an SFP Items required None Note This is a...

Page 44: ...appropriate port slot The latch prong locks and prevents the SFP from being removed accidentally Note The SFP is keyed so that it can only be correctly inserted into the port If the module does not sl...

Page 45: ...thernet port to indicate port status and link speed One LED in the center of the back panel to indicate the overall switch status v One universal input power supply without an ac switch v Five fans Tw...

Page 46: ...owing regulations v FCC Rules and Regulations Part 15B Class A level v CISPR22 Class A v EN55022 Class A v VCCI Class A ITE v AS NZS 3548 Class A System architecture Nonblocking shared memory switch S...

Page 47: ...4 in Width 42 8 cm 16 9 in Weight 3 9 kg 8 5 lbs Environmental specifications Table 12 lists the environmental ranges that are acceptable when the 3534 Model F08 is operating and when it is nonoperati...

Page 48: ...line protection Fused in hot line Memory specifications The 3534 Model F08 contains the types and amounts of memory listed in Table 14 The centralized memory maximizes switch throughput by guaranteein...

Page 49: ...n 7 is used this signal must always be driven high using the pinouts listed in Table 15 Table 15 Cabling pinouts if pin 7 is used Pin Signal Description 1 2 TxData Transmit data 3 RxData Receive data...

Page 50: ...unty deviations TUV GS Germany 89 336 EEC EN 55022 1998 Class A EN 60825 1 1994 A11 2 EN 61000 4 2 Severity Level 3 for Electro Static Discharge EN 61000 4 3 Severity Level 3 for Radiated Fields EN 61...

Page 51: ...figuration worksheet v Zone definition worksheet v Zone configuration worksheet Make as many copies of the blank worksheets as you need to plan the installation of your switches Give your system admin...

Page 52: ...hannel IP address FC netmask WWN Role Syslog daemon IP address Users defined access level SNMP information System description System contacts System location Event trap level 0 5 Enable authentication...

Page 53: ...Port configuration worksheet Table 18 Port configuration worksheet Port number Device name Device port Cable length Port type Notes Cable number 0 1 2 3 4 5 6 7 Appendix B Blank planning worksheets 35...

Page 54: ...definition worksheet Zone member type switch port WWN Zone member Zone configuration name Comments Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P 36 IBM TotalStorage SAN Fibre Channel Sw...

Page 55: ...et Zone member type switch port WWN Zone member Zone configuration name Connects to Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port ID P Port I...

Page 56: ...38 IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 57: ...OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warran...

Page 58: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a...

Page 59: ...tro Magnetic Compatibility EMC Directive 89 336 EEC and the Complementary Directives 92 31 EEC and 93 68 EEC v Low Voltage Directive LVD 73 23 EEC and the Complementary Directive 93 68 EEC v EN50082 2...

Page 60: ...22 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkstoerungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Massnahmen durchzufuehren und d...

Page 61: ...legend of ownership on each copy of Machine Code you make You may transfer possession of Machine Code and its media to another party only with the transfer of the Machine on which the Machine Code is...

Page 62: ...44 IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Page 63: ...ned to the port See also arbitrated loop physical address alias server A fabric software facility that supports multicast group management AL_PA See arbitrated loop physical address American National...

Page 64: ...today the CPU is often a microchip In either case the centrality of a processor or processing unit depends on the configuration of the system or network in which it is used chassis The metal frame in...

Page 65: ...nage the exchange of frames across the fabric between source and destination See also end to end flow control buffer to buffer credit end to end flow control Governs flow of class 1 and class 2 frames...

Page 66: ...protocol fibre channel service protocol FSP The common protocol for all fabric services transparent to the fabric type or topology See also fibre channel service fibre channel shortest path first FSPF...

Page 67: ...initiator A server or workstation on a fibre channel network that initiates communications with storage devices See also target in order delivery IOD A parameter that when set guarantees that frames a...

Page 68: ...ating mode participating mode loop port state machine LPSM The logical entity that performs arbitrated loop protocols and defines the behavior of L_ports when they require access to an arbitrated loop...

Page 69: ...que identifier assigned to a fibre channel port Communicated during login and port discovery POST See power on self test power on self test POST A series of diagnostics that are automatically run by a...

Page 70: ...re devices SDR Single data rate sequence A group of related frames transmitted in the same direction between two N_ports SERDES Serializer deserializer service rate The rate at which an entity can ser...

Page 71: ...Internet protocol transmission word A group of four transmission characters trap SNMP The message sent by an SNMP agent to inform the SNMP management station of a critical error See also simple networ...

Page 72: ...de the zone See also zoning zone alias An alias for a set of port numbers or WWNs Zone aliases can be used to simplify the entry of port numbers and WWNs For example host could be used as an alias for...

Page 73: ...label checks x xi configuration parameters 16 configuring the switch 15 16 connecting the switch 17 customer setup caution notice ix 10 D danger notices electrical outlet ix xii 10 15 example ix line...

Page 74: ...tatement 42 L labels power supply cover caution x safety check x xi labels continued SFP x laser safety caution notice xii LEDs activity interpreting 19 back panel 2 21 front panel 2 19 patterns 20 22...

Page 75: ...al port specifications 30 SES management interface 3 SFP installing 26 SFP continued label x removing 25 replacing 25 slide rack mount 12 13 14 15 SNMP management interface 3 software updates getting...

Page 76: ...ient air 9 terminators for optical ports xii TotalStorage Specialist management interface 3 trademarks 40 translations of safety notices ix Trunking application 3 turning the switch on and off 19 U un...

Page 77: ...in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Appli...

Page 78: ...artment Dept M86 Bldg 050 3 5600 Cottle Road San Jose CA 95193 0001 U S A _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 79: ......

Page 80: ...Part Number 18P4749 Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7631 00 1P P N 18P4749...

Page 81: ...Spine information IBM TotalStorage SAN Fibre Channel Switch 3534 Model F08 Installation Guide...

Reviews: