![IBM System x3950 X6 Product Manual Download Page 34](http://html1.mh-extra.com/html/ibm/system-x3950-x6/system-x3950-x6_product-manual_4733466034.webp)
IBM System x3950 X6
34
Physical and electrical specifications
Dimensions and weight:
Height: 351 mm (13.7 in.)
Width: 482 mm (19.0 in.)
Depth: 804 mm (31.6 in)
Depth with cable management brackets installed: 836 mm (32.9”)
Depth with Full-length I/O Book installed: 921 mm (36.2 in)
Weight:
Minimum configuration: 84.5 kg (186.3 lb)
o
Typical configuration: 88.2 kg (194.5 lb)
o
Maximum configuration: 110.0 kg (242.6 lb)
o
Supported environment:
Air temperature:
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
o
Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
o
Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
o
Humidity:
Server on: 8% - 85%, maximum dew point 24 °C
o
Server off: 8% - 85%, maximum dew point 27 °C
o
Electrical:
Models with 1400 W AC power supplies:
o
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
o
Maximum configuration: 3.2 kVA
o
Models with 900 W AC power supplies:
o
100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.7 A
200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
o
Maximum configuration: 2.0 kVA
o
Models with 750 W DC power supplies:
o
-40 to -75 (nominal) V DC
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
o
Maximum configuration: 1.7 kVA
o