T091: Tape Alert 56 - Unload Failure
Description
GUI Description: The tape drive encountered a problem while unloading a
tape cartridge.
Explanation: When attempting to unload a tape, a drive brick hardware
malfunction can prevent the tape from being ejected. The tape may actually
be stuck in the drive.
Detection Scenario
After unsuccessfully attempting to unload a tape, the drive generates a Tape
Alert 56, which is noticed by the library.
Root Causes
v
A drive hardware error that prevents the tape from being unloaded.
v
A damaged tape that cannot be unloaded from the drive.
Possible FRU Replacements
v
Drive sled
Resolution
Perform “DR078: Resolve Tape Load/Unload Failure” on page 6-83.
T092: Unreadable Branding Identifier
Description
GUI Description: The library could not read the branding identifier.
Explanation: The library logic learns the branding of the system by reading
an internal label on the 5U Control Module. The branding identifier is
located on the same label as the OEM Chassis serial number and WWN. It is
the third barcode line on the label and it starts with an "I" followed by the
IBM Library S/N such as "I13xxxxx". This is done at first boot up from a
“cleared to ship” condition in order to establish the library personality. It is
also done on subsequent boot ups to confirm that the Compact Flash
memory card is in the proper library.
The library will report this ticket when it cannot read the library branding
code but it has confirmed functionality of the bar code reading system by
successfully reading some other bar code label in the library. When T092 is
posted, the user can be confident that at least one other bar code label has
been read. For example, bar codes that can be used to check functionality
are: WWN or OEM SN (in CM cases).
Different tickets will be posted if there are motion-related problems, scanner
communication problems, etc.
Detection Scenario
Picker cannot accurately read the IBM identifier barcode on the control or
expansion module label. See Source Location posted in this ticket to identify
which module.
Root Cause
Label may be damaged or missing.
Possible FRU Replacements
v
Module (EM or CM) - only dispatch this FRU if the label is missing or
damaged.
v
Picker Assembly
Resolution
Perform “DR080: Resolve Unreadable Branding” on page 6-84.
Chapter 6. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)
6-43
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...