background image

4.

Turn on the power to only the expansion units, making sure you turn them on within 5 minutes of
each other.

5.

After you have powered on the storage expansion units, turn on the N3220 filers.

Note:

It takes the LEDs on the system power supplies a few seconds to illuminate.

The system begins to boot, and then it stops at the first installation question, which is displayed on
the console window.

6.

Use the console interface to answer the setup questions for each controller module in your system.
Use the data you collected with the Configuration worksheet.

7.

After you complete the setup, check the licenses on the N3220 filer controller modules by entering
the following command:

license

Add any missing licenses by entering the following command for each missing license:

license add <license_code>

where

<license_code>

is the license code for the product.

Note:

Clustering must be licensed on both nodes in an N3220 HA pair.

8.

Reboot the nodes by entering the following command:

reboot

9.

Enable clustering by entering the following command on one node's console:

cf enable

10.

Check each node's status by entering the following command:

cf status

Initial setup is now complete for a high availability N3220 filer.
Refer to the

Data ONTAP High Availability and MetroCluster Configuration Guide for 7-Mode

to verify

that the system is set up correctly and ready to operate.

11.

IBM recommends that you enable AutoSupport and then use the AutoSupport feature to view the
health of the system.

Setting up and booting the system in Clustered Data ONTAP

For detailed information about setting up and booting your system in Clustered Data ONTAP, refer to

Clustered Data ONTAP Software Setup Guide

.

Installation and setup instructions

11

Summary of Contents for System Storage N3220

Page 1: ...IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32 2202 02...

Page 2: ...l Business Machines Corporation in the United States other countries or both A complete and current list of other IBM trademarks is available on the web at www ibm com legal copytrade shtml Data ONTAP...

Page 3: ...shelf IDs 5 Setting EXN4000 or EXN1000 storage expansion unit shelf IDs 6 Attaching the cable management arms 6 Connecting the N3220 filer to a network 7 Connecting the system to expansion units 9 In...

Page 4: ...iv...

Page 5: ...orage N series Introduction and Planning Guide v IBM System Storage N series Safety Notices v IBM Environmental Notices and User Guide v IBM System Storage N series support website at www ibm com stor...

Page 6: ...v 2 Phillips screwdriver and slotted screwdriver Installing in a non IBM rack The rack installation instructions provided in this document apply specifically to the installation of the N series produ...

Page 7: ...y LED 4 Shelf activity LED 10 Disk drive fault LED 5 Two digit shelf ID digital display 11 Right mounting flange 6 Button for changing the shelf ID Note Disk drive bays are numbered horizontally start...

Page 8: ...Channel option 13 AC fault LED 6 Controller modules 1 or 2 depending on the model 14 Fan fault LED 7 Serial console port 15 Power supplies 2 each with integrated fans 8 Remote Management port wrench...

Page 9: ...Setup Instructions v General information kit containing warranty safety and environmental information v Software license 18 32 kg 39 7 70 5 lbs svc00167 CAUTION The weight of this part or unit is 25...

Page 10: ...in Figure 3 2 Refer to Figure 4 on page 3 At the front of the rack position the right hand rail in the rack at the appropriate EIA location Make sure that the two locating pins seat properly in holes...

Page 11: ...part or unit is 25 4 kg 56 0 lb Use two people to lift an N3220 filer into a rack 1 If the N3220 filer front bezel is attached to the expansion unit carefully remove the bezel by pulling out on the re...

Page 12: ...te and the rack frame rail into the threaded rail nuts Tighten the screws using a screwdriver 4 Replace the front bezel of the N3220 filer 5 From the back of the rack attach a rear tie down plate 1 to...

Page 13: ...Visually verify that the shelf ID for each SAS storage expansion unit is unique If an ID is not unique set the ID 1 Remove the front bezel if you have not already removed it 2 Press and hold the shelf...

Page 14: ...helf ID buttons on the EXN1000 are in the same relative position For N3220 the Shelf ID button should be in 4 GB mode Attaching the cable management arms Using the following instructions attach cable...

Page 15: ...steps depending on your configuration v For 10 100 1000 setup in 7 Mode Connect the system to the network by plugging the network cables into the networking ports labeled e0a e0b e0c and e0d Figure 1...

Page 16: ...e0d n3220002 1 2 3 1 2 LNK SPD LNK SPD e1a e1b ACT LNK ACT LNK 1 1 8 7 10 12 14 16 9 11 13 15 3 4 AC 2 1 Figure 12 Cabling the networking and management ports for 10 GbE connections in 7 Mode n3220003...

Page 17: ...ilability configurations provides redundancy for the path from each controller to every storage expansion unit in the configuration For detailed information about cabling N series SAS storage expansio...

Page 18: ...equired port usage and specifications for optional Mezzanine adapters supported by your N3220 system refer to the IBM System Storage N Series Introduction and Planning Guide Installing the power cable...

Page 19: ...ng license license add license_code where license_code is the license code for the product Note Clustering must be licensed on both nodes in an N3220 HA pair 8 Reboot the nodes by entering the followi...

Page 20: ...12...

Page 21: ...your system All other storage expansion units within each loop must have unique IDs between 2 and 7 and must be placed in consecutive order v For SAS storage expansion units All storage expansion uni...

Page 22: ...ration Guide for your version of Data ONTAP v Data ONTAP Data Protection Tape Backup and Recovery Guide for your version of Data ONTAP v Data ONTAP Data Protection Online Backup and Recovery Guide for...

Page 23: ......

Page 24: ...Part Number 00GM241 Printed in USA GA32 2202 02 1P P N 00GM241...

Reviews: