background image

Table

 

8.

 

DS4000

 

FC2-133

 

Adapter

 

activity

 

Green

 

LED

 

Amber

 

LED

 

Activity

 

Description

 

Off

 

Off

 

Power

 

off

 

The

 

server

 

adapter

 

is

 

not

 

receiving

 

power.

 

The

 

server

 

is

 

powered

 

off.

 

On

 

On

 

Power

 

The

 

FC2-133

 

Adapter

 

is

 

receiving

 

power

 

from

 

the

 

PCI

 

or

 

PCI-X

 

slot

 

but

 

is

 

not

 

initialized

 

by

 

the

 

adapter

 

firmware.

 

On

 

Off

 

Online

 

The

 

FC2-133

 

Adapter

 

is

 

successfully

 

initialized

 

by

 

the

 

adapter

 

firmware

 

and

 

is

 

in

 

a

 

ready

 

state.

 

The

 

adapter

 

firmware

 

is

 

initialized

 

when

 

the

 

adapter

 

BIOS

 

code

 

is

 

loaded,

 

Ctrl-Q

 

is

 

pressed,

 

or

 

the

 

operating

 

system

 

driver

 

is

 

loaded.

 

Off

 

On

 

Signal

 

acquired

 

The

 

FC2-133

 

Adapter

 

firmware

 

is

 

performing

 

or

 

waiting

 

to

 

perform

 

Fibre

 

Channel

 

loop

 

initialization.

 

Off

 

Flashing

 

twice

 

per

 

second

 

Loss

 

of

 

synchronization

 

The

 

FC2-133

 

Adapter

 

has

 

detected

 

a

 

loss

 

of

 

synchronization

 

condition

 

from

 

the

 

adapter

 

Fibre

 

Channel

 

receiver

 

and

 

is

 

attempting

 

to

 

resynchronize.

 

A

 

loss

 

of

 

synchronization

 

condition

 

might

 

occur

 

when

 

a

 

degraded

 

optical

 

signal

 

is

 

received

 

from

 

the

 

LC-LC

 

Fibre

 

Channel

 

cable

 

or

 

optical

 

interface

 

connector.

 

Flashing

 

twice

 

per

 

second

 

Flashing

 

twice

 

per

 

second

 

Firmware

 

error

 

The

 

FC2-133

 

Adapter

 

firmware

 

has

 

detected

 

an

 

unrecoverable

 

error

 

condition.

 

Off

 

Flashing

 

once

 

per

 

second

 

Beacon

 

The

 

adapter

 

is

 

responding

 

to

 

a

 

Beacon

 

command

 

from

 

a

 

HBA

 

management

 

program.

  

The

 

jumpers

 

on

 

the

 

HBA

 

set

 

the

 

default

 

state

 

of

 

the

 

laser

 

and

 

are

 

set

 

at

 

the

 

factory

 

with

 

a

 

jumper

 

plug

 

on

 

pins

 

2-3

 

of

 

the

 

J3

 

and

 

J4

 

jumpers.

 

 

Attention:

  

Changing

 

the

 

jumper

 

settings

 

can

 

result

 

in

 

the

 

HBA

 

being

 

inoperable.

 

Preinstallation

 

procedures

 

Complete

 

the

 

following

 

tasks

 

before

 

you

 

begin

 

the

 

installation:

 

v

   

Read

 

“Handling

 

static-sensitive

 

devices”

 

on

 

page

 

4.

 

v

   

Read

 

“What

 

you

 

need

 

for

 

the

 

installation”

 

on

 

page

 

5.

 

v

   

Write

 

down

 

the

 

serial

 

number

 

of

 

the

 

DS4000

 

FC2-133.

 

Each

 

adapter

 

has

 

a

 

unique

 

serial

 

number.

 

If

 

the

 

nonvolatile

 

random

 

access

 

memory

 

(NVRAM)

 

(also

 

referred

 

to

 

as

 

NOVRAM)

 

is

 

damaged,

 

the

 

system

 

prompts

 

you

 

for

 

the

 

DS4000

 

FC2-133

 

serial

 

number.

 

Figure

 

3

 

on

 

page

 

4

 

shows

 

the

 

location

 

of

 

the

 

serial

 

number

 

label.

 

Chapter

 

1.

 

Preparing

 

and

 

installing

 

the

 

DS4000

 

FC2-133

 

3

Summary of Contents for System Storage DS4000

Page 1: ...IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide GC26 7737 00 ...

Page 2: ......

Page 3: ...IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide GC26 7737 00 ...

Page 4: ...d the general information under Notices on page 31 First Edition January 2005 Copyright International Business Machines Corporation 2005 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 5: ...rmation help and service xxvii Before you call xxvii Using the documentation xxviii Web sites xxviii Software service and support xxviii Hardware service and support xxix Fire suppression systems xxix How to send your comments xxix Chapter 1 Preparing and installing the DS4000 FC2 133 1 Overview 1 Overview of fibre channel 1 DS4000 FC2 133 features 1 DS4000 FC2 133 components 2 Preinstallation pro...

Page 6: ...cifications 25 Chapter 5 Troubleshooting 27 Hardware problems 27 Software problems 27 System configuration problems 27 Fibre channel problems 28 Appendix Accessibility 29 Notices 31 Trademarks 31 Important notes 32 Electronic emission notices 32 Class B statements 32 Federal Communications Commission FCC statement 32 Industry Canada Class B emission compliance statement 33 Avis de conformité à la ...

Page 7: ...Glossary 37 37 Index 47 Contents v ...

Page 8: ...vi IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 9: ...Figures 1 Installation process flow by current publications xix 2 DS4000 FC2 133 components 2 3 DS4000 FC2 133 serial number label 4 Copyright IBM Corp 2005 vii ...

Page 10: ...viii IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 11: ...s by user tasks xxii 5 TotalStorage DS4100 SATA Storage Server document titles by user tasks xxiii 6 TotalStorage DS4000 Storage Manager Version 9 titles by user tasks xxiv 7 TotalStorage DS4000 and DS4000 related document titles by user tasks xxv 8 DS4000 FC2 133 Adapter activity 3 9 Examples of flasutil command line options 11 10 DS4000 FC2 133 operating environment 25 11 DS4000 FC2 133 specific...

Page 12: ...x IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 13: ...än tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet Antes de instalar este produto leia as Informações sobre S...

Page 14: ...e v Keep your tool case away from walk areas so that other people will not trip over it v Do not wear loose clothing that can be trapped in the moving parts of a machine Ensure that your sleeves are fastened or rolled up above your elbows If your hair is long fasten it v Insert the ends of your necktie or scarf inside clothing or fasten it with a nonconductive clip approximately 8 centimeters 3 in...

Page 15: ...erson familiar with the power off controls is near you Remember Another person must be there to switch off the power if necessary Use only one hand when working with powered on electrical equipment keep the other hand in your pocket or behind your back Remember There must be a complete circuit to cause electrical shock By observing the previous rule you might prevent a current from passing through...

Page 16: ...rted into the product v Avoid contact with other people v Wear a grounded wrist strap against your skin to eliminate static on your body v Prevent the part from touching your clothing Most clothing is insulative and retains a charge even when you are wearing a wrist strap v Select a grounding system such as those listed below to provide protection that meets the specific service requirement Note T...

Page 17: ...ecks with the power off and with the power cord disconnected 1 Check the exterior covers for damage loose broken or sharp edges 2 Check the power cord for the following conditions a A third wire ground connector in good condition Use a meter to measure third wire ground continuity for 0 1 ohm or less between the external ground pin and frame ground b The power cord should be the appropriate type a...

Page 18: ...xvi IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 19: ...low with new names are functionally equivalent and fully interoperable Each DS4000 product retains full IBM service as outlined in service contracts issued for analogous FAStT products Table 1 Mapping of FAStT names to DS4000 Series names Current FAStT Product Name New DS4000 Product Name IBM TotalStorage FAStT Storage Server IBM TotalStorage DS4000 FAStT DS4000 FAStT Family DS4000 Mid range Disk ...

Page 20: ...stems TotalStorage DS4000 Midrange Disk Systems FAStT Stor Srvrs 3 Place a check in the box for the machine type of your DS4000 series product as well as any other attached DS4000 series product s for which you would like to receive information Select Add products The My support page reopens 4 Select Subscribe to email In the Documents area on the next page use the pull down and select Storage 5 O...

Page 21: ...DS4000 Problem Determination Guide Out of Band In Band Make FC Connections SET Link Speed 1GB or 2GB Install Storage Server RAID Controller Enclosure s in Rack Install Network Hardware Prep are Network Connection Install Storage Expansion Enclosure s Determine Management Method For pSeries POWER server and pSeries POWER supported HBA use only sj001046 DS4000 Storage Server publications The followi...

Page 22: ...ion Diagnosis and Maintenance IBM TotalStorage DS4500 Installation and Support Guide GC26 7727 U U U IBM TotalStorage DS4500 Fibre Channel Cabling Instructions GC26 7729 U U IBM TotalStorage DS4500 Storage Server User s Guide GC26 7726 U U U IBM TotalStorage DS4500 Rack Mounting Instructions GC26 7728 U U xx IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 23: ...document titles by user tasks Title User Tasks Planning Hardware Installation Software Installation Configuration Operation and Administration Diagnosis and Maintenance IBM DS4400 Fibre Channel Storage Server User s Guide GC26 7730 U U U U U IBM DS4400 Fibre Channel Storage Server Installation and Support Guide GC26 7731 U U U U IBM DS4400 Fibre Channel Cabling Instructions GC26 7732 U U About thi...

Page 24: ...tion Diagnosis and Maintenance IBM TotalStorage DS4300 Fibre Channel Storage Server Installation and User s Guide GC26 7722 U U U IBM TotalStorage DS4300 Rack Mounting Instructions GC26 7724 U U IBM TotalStorage DS4300 Fibre Channel Cabling Instructions GC26 7725 U U IBM TotalStorage DS4300 SCU Base Upgrade Kit GC26 7740 U U IBM TotalStorage DS4300 SCU Turbo Upgrade Kit GC26 7741 U U IBM TotalStor...

Page 25: ...talStorage DS4100 SATA Storage Server document titles by user tasks Title User Tasks Planning Hardware Installation Software Installation Configuration Operation and Administration Diagnosis and Maintenance IBM TotalStorage DS4100 Installation User s and Maintenance Guide GC26 7733 U U U U U IBM TotalStorage DS4100 Cabling Guide 24P8973 U About this document xxiii ...

Page 26: ...and maintenance IBM TotalStorage DS4000 Storage Manager Version 9 Installation and Support Guide for Windows 2000 Server 2003 NetWare ESX Server and Linux GC26 7706 U U U IBM TotalStorage DS4000 Storage Manager Version 9 Installation and Support Guide for AIX HP UX Solaris and Linux on POWER GC26 7705 U U U IBM TotalStorage DS4000 Storage Manager Version 9 Copy Services User s Guide GC26 7707 U U ...

Page 27: ...Storage DS4000 Hardware Maintenance Manual GC26 7702 U IBM TotalStorage DS4000 Problem Determination Guide GC26 7703 U IBM Fibre Channel Planning and Integration User s Guide and Service Information SC23 4329 U U U U IBM TotalStorage DS4000 FC2 133 Host Bus Adapter Installation and User s Guide GC26 7736 U U IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide G...

Page 28: ...ge 1 includes an overview of the DS4000 FC2 133 features and contains the information and instructions needed to prepare and install the DS4000 FC2 133 Chapter 2 Updating the DS4000 FC2 133 BIOS code and installing device drivers on page 9 provides information for how to update the DS4000 FC2 133 BIOS code Chapter 3 Configuring the DS4000 FC2 133 with Fast UTIL on page 19 provides detailed configu...

Page 29: ...l or extremely hazardous to you A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation Getting information help and service If you need help service or technical assistance or just want more information about IBM products you will find a wide variety of sources available from IBM to assist you This section contains inform...

Page 30: ...and tips to help you solve problems Participating in IBM discussion forums Setting up e mail notification of technical updates about your products v You can order publications through the IBM Publications Ordering System at the following Web site www elink ibmlink ibm com public applications publications cgibin pbi cgi v For the latest information about IBM xSeries products services and support go...

Page 31: ...tures equipment to internal and external standards that require certain environments for reliable operation Because IBM does not test any equipment for compatibility with fire suppression systems IBM does not make compatibility claims of any kind nor does IBM provide recommendations on fire suppression systems How to send your comments Your feedback is important in helping us to provide the most a...

Page 32: ...u grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you xxx IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 33: ...uper computers v Workstations v Storage devices v Servers Overview of fibre channel Fibre channel is a high speed data transport technology used for mass storage and networking By using a fibre channel arbitrated loop FC AL 126 fibre channel devices can be supported compared to 15 small computer system interface SCSI devices with Ultra SCSI The DS4000 FC2 133 uses multimode shortwave optical inter...

Page 34: ...33 components Figure 2 identifies the DS4000 FC2 133 components that are referred to in this document ISP2312 J3 J4 Bracket Amber LED Green LED Optical interface connector Each port has its own set of status light emitting diodes LEDs Table 8 on page 3 describes the green and amber LEDs and the activity that is indicated by the LEDs For more information about the DS4000 FC2 133 LED activity and tr...

Page 35: ...d optical signal is received from the LC LC Fibre Channel cable or optical interface connector Flashing twice per second Flashing twice per second Firmware error The FC2 133 Adapter firmware has detected an unrecoverable error condition Off Flashing once per second Beacon The adapter is responding to a Beacon command from a HBA management program The jumpers on the HBA set the default state of the...

Page 36: ...le and possibly damage the device v While the device is still in its static protective package you should hold the device and touch an unpainted metal part of the system unit for at least 2 seconds This drains static electricity from the package and from your body v Remove the device from its package and install it directly into your system unit without setting it down If it is necessary to set th...

Page 37: ...ck the size of the storage server to verify whether you need the Low Profile 2U adapter bracket If you need to install the Low Profile 2U bracket go to step 1 Otherwise go to step 2 1 Complete the following steps to install the Low Profile 2U adapter bracket a Remove your DS4000 FC2 133 from the static protective package Set it down on a nonconductive static protected surface place it component si...

Page 38: ...ee the documentation that comes with the server to determine the slot type 7 Remove the expansion slot cover Before you remove the cover see the documentation that comes with the server for specific removal instructions Attention If you try to install the DS4000 FC2 133 into a PCI bus master slot that does not conform to the PCI specification you might damage the DS4000 FC2 133 8 Align the adapter...

Page 39: ...t is displayed is correct go to Chapter 2 Updating the DS4000 FC2 133 BIOS code and installing device drivers on page 9 for detailed instructions on how to update the DS4000 FC2 133 BIOS code If the information that is displayed is not correct and you have checked the adapter configuration go to Chapter 5 Troubleshooting on page 27 for problem solving information Chapter 1 Preparing and installing...

Page 40: ...8 IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 41: ...see Updating the BIOS code and NVRAM from the support CD or by creating and using a BIOS Update Utility diskette see Updating the BIOS code and NVRAM from the BIOS Update Utility diskette on page 12 To install the device drivers see Installing the DS4000 FC2 133 device drivers on page 15 Note For the latest information about supported operating systems versions of device drivers utilities and docu...

Page 42: ... no address specified then display the serial number of all adapters V xxxx Display current version number of BIOS on adapters at address xxxx If no address specified then display the BIOS version of all adapters C xxxx Verify Flash of adapter at address xxxx If no address specified verify the Flash of all adapters Y xxxx Display port name of adapter at address xxxx If no address specified then di...

Page 43: ...ddresses displays At the command prompt type the appropriate I O address and press Enter 4 The following option menu displays F Write Flash W Copy Flash to file QLxxROM SAV S Display serial number V Display current BIOS version C Verify Flash Y Display port name L Write NOVRAM A Write NOVRAM and defaults D Copy NOVRAM to file QLxxNVRM SAV U Update BIOS NOVRAM defaults X Verify NOVRAM Notes a All o...

Page 44: ...and d tools dsk4w32 d images biosnvrm 23x0 2342_xxx img a Where d is the CD ROM drive and a is the diskette drive 4 Press Enter 5 Remove the support CD from the CD ROM drive 6 Remove the diskette from the diskette drive and label the diskette appropriately For Linux Complete the following steps to create a BIOS Update Utility diskette for Linux from the IBM TotalStorage DS4000 FC2 133 Dual Port Ho...

Page 45: ...he diskette drive and restart the server Your server displays a DOS prompt 2 Update the BIOS in the flash utility by typing the following command flasutil f Press Enter 3 Update the NVRAM by typing the following command flasutil l Press Enter 4 Update the standard BIOS defaults in the flash utility to the new defaults from the NVRAM files by typing the following command flasutil u Press Enter 5 To...

Page 46: ...ate all adapters N filename ext Use filename ext instead of NVRMxx0 DAT T Multiport Fibre Channel adapter X xxxx Verify NOVRAM of adapter at address xxxx Notes a All of the listed options are supported and you can run them from the command line Options L D U N T and X might not display b The command line option is not case sensitive Either f or F can be used to initiate the adapter flash BIOS upda...

Page 47: ...to the following Web site www ibm com pc support Using IBM FastT MSJ utility This section provides an overview of the IBM FastT MSJ Management Suite Java utility that can be used by advanced users to customize the configuration of the IBM FC2 133 HBA when it is installed in a server For more detailed information see the IBM DS4000 Management Suite Java User s Guide version 1 0 or later that is ava...

Page 48: ...he IBM DS4000 Host Bus Adapters For the latest information about the FastT MSJ utility go to the IBM DS4000 Support Web site www ibm com servers storage support disk The latest instructions and system requirements are in the documentation that come with the utility Features The FAStT MSJ utility lets you v Set the FAStT MSJ utility options v Connect to hosts v Disconnect from a host v View detaile...

Page 49: ...the file is valid the application then compares the version of the file with the adapter flash version that is currently installed If the installed adapter version is the same or newer than the file flash version you are trying to install the application asks if you still want to update the flash If the firmware update fails an error message displays Update NVRAM When you click Update NVRAM in the...

Page 50: ...18 IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 51: ... by an IBM technical support representative or by the installation instructions The default settings are for a typical Microsoft Windows installation See the DS4000 FC2 133 device driver readme file of the appropriate operating system for the required NVRAM setting modifications for that operating system Note An alternative method to update the BIOS and the adapter NOVRAM settings is to use the IB...

Page 52: ...located on the noncomponent side of the adapter See Figure 3 on page 4 for the location of the serial number label Interrupt level The interrupt level is the interrupt that is used by the DS4000 FC2 133 The interrupt level can change when the operating system is installed Adapter port name This is the worldwide port name Host adapter BIOS When this setting is Disabled the ROM BIOS on the FC2 133 H...

Page 53: ...re executed until the current command finishes executing The valid options for this setting are 1 256 The default is 255 LUNs per Target This setting specifies the number of LUNs per target Multiple LUN support is typically for redundant array of independent disks RAID boxes that use LUNs to map drives The default is 0 For host operating systems other than Microsoft Windows one may need to change ...

Page 54: ...d generating an interrupt The default is 0 Selectable boot settings When you set the Selectable Boot Settings option to Enabled you can select the worldwide port name of the fibre channel hard disk from which you want to start up boot When this option is set to Enabled the node starts from the selected fibre channel hard disk ignoring any IDE or SCSI hard disks that are attached to your server Whe...

Page 55: ... utility Attention When you perform a low level format it removes all data on the disk You can use the Fibre Channel Disk Utility option to scan the fibre channel loop bus and list all the connected devices by loop ID You can select a disk device and perform a low level format or verify the disk media or data Loopback data test You can use the Loopback Data Test option to verify the basic transmit...

Page 56: ...24 IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 57: ...PCI X bus at 50 MHz 100 MHz and 133 MHz v PCI transfer rate 264 MBps maximum burst rate for 33 MHz operation ISP2312 chip v Support for dual address bus cycles Fibre channel specifications v Fiber optic media shortwave multimode 50 micron cable v Bus transfer rate 200 MBps maximum at half duplex and 400 MBps maximum at full duplex v Interface chip ISP2312 PCI X QLA23xx boards v Support for both FC...

Page 58: ...KB transmit and 6 KB receive frame buffer first in first out FIFO for each data channel Connectors external v Two LC style connectors that support non OFC multimode fiber optic cabling using a small form factor SFF fiber optic transceiver module v Support 50 125 FC cable length up to 550 m 1804 ft when operating at 1 Gbps or up to 300 m 984 ft when operating at 2 Gbps Form factor 5 15 cm x 16 93 c...

Page 59: ... nonstandard PCI connectors v Verify that the Fast UTIL data rate setting is correct The Fast UTIL data rate setting must match the speed of the device to which you are connected See Chapter 3 Configuring the DS4000 FC2 133 with Fast UTIL on page 19 v Verify that all peripheral devices are turned on See Fibre channel problems on page 28 for information about how to display the attached fibre chann...

Page 60: ... Verify that all of the fibre channel devices were turned on before you turned on the server v Ensure that all cables are connected properly v Verify that you configured your RAID storage subsystems using the utilities that were provided by the manufacturer v If your fibre channel switch supports zoning make sure that your peripheral device is configured to the same switch zone as the DS4000 FC2 1...

Page 61: ...ys v Tab Moves keyboard focus to the next component or to the first member of the next group of components v Shift Tab Moves keyboard focus to the previous component or to the first component in the previous group of components v Arrow keys Move keyboard focus within the individual components of a group of components Table 12 DS4000 Storage Manager alternate keyboard operations Short cut Action F1...

Page 62: ...ior is the same for contiguous and non contiguous selection of drives End Page Down Move keyboard focus to the last item in the list Esc Close the current dialog does not require keyboard focus Home Page Up Move keyboard focus to the first item in the list Shift Tab Move keyboard focus through components in the reverse direction Ctrl Tab Move keyboard focus from a table to the next user interface ...

Page 63: ...NY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are period...

Page 64: ... currently supported drives available from IBM Maximum memory may require replacement of the standard memory with an optional memory module IBM makes no representation or warranties regarding non IBM products and services that are ServerProven including but not limited to the implied warranties of merchantability and fitness for a particular purpose These products are offered and warranted solely ...

Page 65: ...ended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received includ...

Page 66: ...nterference received including interference that may cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformité à la réglementation d Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Australia and New Zealand Class A statement Attention This is a Cl...

Page 67: ...domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Taiwan electrical emission statement Japanese Voluntary Control Council for Interference VCCI statement Notices 35 ...

Page 68: ...36 IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 69: ... standard for IBM compatibles It extends the XT bus architecture to 16 bits and also allows for bus mastering although only the first 16 MB of main memory are available for direct access agent A server program that receives virtual connections from the network manager the client program in a Simple Network Management Protocol Transmission Control Protocol Internet Protocol SNMP TCP IP network mana...

Page 70: ...t customer replaceable unit CRU An assembly or part that a customer can replace in its entirety when any of its components fail Contrast with field replaceable unit FRU cyclic redundancy check CRC 1 A redundancy check in which the check key is generated by a cyclic algorithm 2 An error detection technique performed at both the sending and receiving stations dac See disk array controller dar See di...

Page 71: ...ched to it The fabric is responsible for routing frames between source and destination N_ports using address information in the frame header A fabric can be as simple as a point to point channel between two N ports or as complex as a frame routing switch that provides multiple and redundant internal pathways within the fabric between F_ports fabric port F_port In a fabric an access point for conne...

Page 72: ...torage partition topology that defines a logical collection of host computers that require shared access to one or more logical drives host port Ports that physically reside on the host adapters and are automatically discovered by the DS4000 Storage Manager software To give a host computer access to a partition its associated host ports must be defined hot swap To replace a hardware component with...

Page 73: ...face SCSI bus to distinguish among up to eight devices logical units with the same SCSI ID loop address The unique ID of a node in fibre channel loop topology sometimes referred to as a loop ID loop group A collection of storage area network SAN devices that are interconnected serially in a single loop circuit loop port A node port N_port or fabric port F_port that supports arbitrated loop functio...

Page 74: ...s part of configuring a drive into the kernel ODM See Object Data Manager out of band Transmission of management protocols outside of the fibre channel network typically over Ethernet partitioning See storage partition parity check 1 A test to determine whether the number of ones or zeros in an array of binary digits is odd or even 2 A mathematical operation on the numerical representation of the ...

Page 75: ...ring See also Global Mirroring Metro Mirroring ROM See read only memory router A computer that determines the path of network traffic flow The path selection is made from several paths based on information obtained from specific protocols algorithms that attempt to identify the shortest or best path and other criteria such as metrics or protocol specific destination addresses RVSD See recoverable ...

Page 76: ...ervers storage products networking products software and services See also fabric Storage Array Identifier SAI or SA Identifier The Storage Array Identifier is the identification value used by the DS4000 Storage Manager host software SMClient to uniquely identify each managed storage server The DS4000 Storage Manager SMClient program maintains Storage Array Identifier records of previously discove...

Page 77: ...peer connectivity functions for both local and wide area networks trap In the Simple Network Management Protocol SNMP a message sent by a managed node agent function to a management station to report an exception condition trap recipient Receiver of a forwarded Simple Network Management Protocol SNMP trap Specifically a trap receiver is defined by an Internet Protocol IP address and port to which ...

Page 78: ...46 IBM TotalStorage DS4000 FC2 133 Dual Port Host Bus Adapter Installation and User s Guide ...

Page 79: ... Installation and Support Guide for Windows NT xxiv DS4000 FAStT product renaming xvii DS4100 Storage Server library xxiii DS4300 Fibre Channel Storage Server library xxii DS4400 Storage Server library xxi DS4500 Fibre Channel Storage Server library xix E electrical safety xiii ESD sensitive devices handling xiv F Fast UTIL settings host adapter settings 20 using 19 Fast UTIL starting 19 FAStT DS4...

Page 80: ...static sensitive devices handling 4 system configuration problems 27 T trademarks 31 troubleshooting fibre channel 28 hardware 27 installation problems 27 system configuration 27 U user tasks DS4000 Storage Manager xxiv DS4100 Storage Server xxiii DS4300 Fibre Channel Storage Server xxii DS4400 Fibre Channel Storage Server xxi DS4500 Fibre Channel Storage Server xix related documents xxv W web sit...

Page 81: ...ation in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applicable to your tasks h h h h h Please tell us how we can improve this book Thank you for your responses May we contact you h Yes h No When you send comments to IBM you grant IBM a nonexclusive ri...

Page 82: ...ent GZW 9000 South Rita Road Tucson Arizona U S A 85744 0001 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...