Show Controller Diagnostic Status
This command returns the status of controller diagnostics started by the
start controller diagnostic
command. If the diagnostics have finished, the entire results of the diagnostic tests are shown. If the
diagnostic tests have not finished, only the results of the of the tests that are finished are shown. The
results of the test are shown on the terminal, or you can write the results to a file.
Syntax
show controller [(a | b)] diagnosticStatus [file=filename]
Parameters
Parameter
Description
controller
The setting to return information about a specific controller
in the storage subsystem. Valid controller identifiers are
a
or
b
, where
a
is the controller in slot A, and
b
is the controller
in slot B. Enclose the controller identifier in square brackets
([ ]).
file
The name of the file that contains the results of the
diagnostic tests. This command does not automatically
append a file extension to the file name. You must add an
extension when you enter the file name.
Show Controller NVSRAM
This command returns a list of the NVSRAM byte values for the specified host type. If you do not enter
the optional parameters, this command returns a list of all of the NVSRAM byte values.
Syntax
show (allControllers | controller [(a | b)]) NVSRAM [hostType=
hostTypeIndexLabel
| host=”
hostName
”]
Parameters
Parameter
Description
allControllers
The setting to return information about both controllers in the
storage subsystem.
controller
The setting to return information about a specific controller in
the storage subsystem. Valid controller identifiers are
a
or
b
,
where
a
is the controller in slot A, and
b
is the controller in
slot B. Enclose the controller identifier in square brackets ([ ]).
hostType
The index label or number of the host type. Use the
show
storageSubsystem hostTypeTable
command to generate a list
of available host type identifiers.
host
The name of the host that is connected to the controllers.
Enclose the host name in double quotation marks (“ ”).
Notes
Use the
show controller NVSRAM
command to show parts of or all of the NVSRAM before using the
set
controller
command to change the NVSRAM values. Before making any changes to the NVSRAM,
contact your IBM Technical Support representative to learn what regions of the NVSRAM you can
modify.
3-254
IBM System Storage DS3000, DS4000, and DS5000: Command Line Interface and Script Commands Programming Guide
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...