Parameters
Parameter
Description
enhancedGlobalMirrorGroup
The name of the Enhanced Global Mirror Group for
which you want to check the synchronization progress.
Enclose the Enhanced Global Mirror Group name in
square brackets ([ ]). If the enhanced global mirror group
name has special characters, you also must enclose the
Enhanced Global Mirror Group name in double
quotation marks (" ") inside square brackets. If the
Enhanced Global Mirror Group name consists only of
numbers, such as "1002," you also must enclose the
enhanced global mirror group name in double quotation
marks (" ") inside square brackets.
synchronizationProgress
Use this optional parameter to display the periodic
synchronization progress of the Enhanced Global Mirror
Group.
Minimum Firmware Level
7.84
Show Cache Backup Device Diagnostic Status
This command returns the status of backup device diagnostic tests started by the
startcacheBackupDevice
diagnostic
command. If the diagnostics have finished, all of the results of the diagnostic tests are shown.
If the diagnostics have not finished, only the results of the diagnostic tests that finished are shown. The
results of the test are shown on the terminal, or you can write the results to a file.
Syntax
show cacheBackupDevice controller [(a | b)] diagnosticStatus [file="fileName"]
Parameters
Parameter
Description
controller
The controller that has the cache backup device on which
you are running the diagnostic tests. Valid controller
identifiers are
a
or
b
, where
a
is the controller in slot A, and
b
is the controller in slot B. Enclose the controller identifier
in square brackets ([ ]). If you do not specify a controller, the
storage management software returns a syntax error.
file
The name of the file that contains the result of the diagnostic
tests. Enclose the file name in double quotation marks (" ").
This command does not automatically append a file
extension to the file name. You must add an extension when
you enter the file name.
Show Cache Memory Diagnostic Status
This command returns the status of cache memory diagnostics started by the
start
controllerdiagnostic
command. If the diagnostics have finished, all of the results of the diagnostic tests
are shown. If all of the diagnostics have not finished, only the results of the diagnostic tests that finished
are shown.
3-250
IBM System Storage DS3000, DS4000, and DS5000: Command Line Interface and Script Commands Programming Guide
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...