Display Support Bundle Collection Schedule
This command displays the schedule for collecting support bundles for all storage subsystems.
Syntax
Attention:
The SM CLI support bundle commands must be run from the SM CLI command line
interface only. They cannot be run from the storage subsystem SM CLI script window. In addition, the
storage subsystem IP addresses are not required. Also, the
-c
parameter is not required to precede the SM
CLI support bundle command.
-supportBundle schedule show
Parameters
None.
Download Drive Firmware
Syntax
Attention:
Possible damage to the storage subsystem configuration – downloading drive firmware
incorrectly can result in damage to the drives or a loss of data access.
This command is intended for downloading a firmware image to only one drive at a time. If you use this
command in a script, make sure that you use this command only once. If you use this command more
than once, the operation can fail. You can download firmware images to all of the drives in a storage
subsystem at onetime by using the download
storageSubsystem driveFirmware
command.
download drive [enclosureID,drawerID,slotID] firmware file="filename"
Parameters
Parameter
Description
drive
The drive to which you want to download the firmware
image. For high-capacity drive enclosures, specify the
enclosure ID value, the drawer ID value, and the slot ID
value for each drive to which you want to download
firmware. For low-capacity drive enclosures, specify the
enclosure ID value and the slot ID value for each drive to
which you want to download firmware. Enclosure ID values
are
0
to
99
. Drawer ID values are
1
to
5
. Slot ID values are
1
to
32
. Enclose the enclosure ID values, the drawer ID values,
and the slot ID values in brackets ([ ]).
file
The file path and the file name of the file that contains the
firmware image. Enclose the file path and the file name of
the firmware image in double quotation marks (" "). For
example:
file="C:\Program Files\CLI\dnld\drvfrm.dlp"
Valid file names have a
.dlp
extension.
Notes
Before trying to download drive firmware, take these precautions:
v
Stop all I/O activity to the storage subsystem before you download the firmware image. The download
drive command blocks all I/O activity until the download finishes or fails; however, as a precaution,
make sure that all I/O activity that might affect the drive is stopped.
Chapter 3. Script Commands
3-125
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...