1.
To help you work safely with Storwize V7000 Unified file modules, read the
safety information in “Safety” on page xi, “Safety statements” on page xiii, and
“Installation guidelines” on page 54.
2.
Turn off the file module and peripheral devices, then label and disconnect both
power cords and all external cables.
3.
Press down on the left and right side latches and pull the server out of the rack
enclosure until both slide rails lock.
4.
Remove the cover, as described in “Removing the cover” on page 83.
5.
Remove PCI riser-card assembly 2, as described in “Removing a PCI riser-card
assembly” on page 99.
6.
Grasp the top of the air baffle and lift the air baffle out of the file module.
Attention:
For proper cooling and airflow, replace all air baffles before you
turn on the file module. Operating the file module with any air baffle removed
might damage file module components.
7.
If you are instructed to return the microprocessor air baffle, follow all
packaging instructions, and use any packaging materials for shipping that are
supplied to you.
Installing the microprocessor 2 air baffle
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
Chapter 4. File module
91
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...