![IBM Storwize V7000 Manual Download Page 112](http://html2.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_manual_3310372112.webp)
T
is the technician port. Never connect a technician port to a network switch.
Table 46. Ethernet connections available with the Storwize V7000 Gen2 control enclosure
Item
Port
Purpose
IP address is
assigned by
InitTool
Use
1
Built-in
Ethernet port 1
1 Gbps external
network
connection
Yes
Management
and service
port for each
canister;
optional iSCSI.
(The Storwize
V7000 control
enclosure must
be able to
communicate
over the
network with
the file
modules.)
2
Built-in
Ethernet port 2
1 Gbps external
network
connection
No
Optional
management
and service
port; optional
iSCSI
3
Built-in
Ethernet port 3
1 Gbps external
network
connection
No
Optional
management
and service
port; optional
iSCSI
4
Ethernet port 4
10 GbE external
network
connection
No
Optional iSCSI
5
Ethernet port 5
10 GbE external
network
connection
No
Optional iSCSI
6
Ethernet port 6
10 GbE external
network
connection
No
Optional iSCSI
7
Ethernet port 7
10 GbE external
network
connection
No
Optional iSCSI
fab10041
3
2
1
2
1
3
1
2
5 6 7
4
3
T
Figure 53. Ethernet ports when an optional 10 Gbps Ethernet interface card is present in PCI
slot 3
92
IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720
Summary of Contents for Storwize V7000
Page 151: ......
Page 152: ...Part Number 00MJ333 Printed in USA SC27 4223 05 1P P N 00MJ333...