The noise emission level that is stated is the declared (upper limit) sound power level, in decibels, for a
random sample of machines. All measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296.
Acoustical Declaration with Noise Hazard Notice
Figure 82 on page 99 indicates the declared noise emissions values in accordance with ISO 9296.
Figure 82. Acoustical Declaration with Noise Hazard Notice
Shock and vibration specifications for Storwize V5100 enclosures
Table 25 on page 99 and Table 26 on page 99 provide the shock and vibration testing results for your
Storwize V5100 system.
Table 25. Shock testing results
Shock categories
Test level
Performance
Operational
5 g 10 ms 1/2 Sine
<=25 g 10 ms
Non-operational
30 g 10 ms 1/2 Sine
<=75 g 11 ms
Table 26. Vibration testing results
Vibration categories
Test level
Performance
Operational
0.21 grms 5-500 Hz Random
Throughput loss <=10% FCAL <= 0.68 grms
Non-operational
1.04 grms 2-200 Hz Random
<=3.12 grms
Shipping
0.3 g 2-200 Hz Sine
<=5 g
Rotational vibration
Normal operation performance
measurements in enclosure with
no external vibration.
Throughput loss for all drives of the same type
within performance profile.
Appendix C. Control enclosure requirements 99