Table 22. LED indicators on drives (continued)
Function
Color
Status
Description
3
Fault
Amber
On
A fault occurred on the
drive. The LED is turned
off when the drive is
removed and replaced.
Flash
The drive is being
identified, a fault might
or might not be
detected.
Off
The installed drive is
operating normally.
Figure 122 on page 115 shows the LEDs on a secondary expansion module.
Figure 122. LEDs on a secondary expansion module
1
Online indicator
2
Fault indicator
Table 23 on page 115 describes the meaning of the LEDs on each secondary expansion module.
Table 23. LED indicators on secondary expansion modules
Function
Color
Status
Description
1
Power
Green
On
The secondary expansion
module is receiving power.
Flashing
Not used.
Off
The secondary expansion
module is not receiving
power.
2
Fault
Amber
On
Not used.
Flash
The secondary expansion
module is being identified.
Off
The secondary expansion
module is operating
normally.
Chapter 2. Installing the system hardware 115