• Do not remove a faulty expansion canister until its replacement is ready to be installed.
• Do not remove an expansion canister from an operational enclosure for more than approximately 10
minutes. The reduction in airflow through the enclosure might cause the enclosure or its components to
shut down to protect from overheating.
About this task
An expansion canister provides SAS connectivity between the 2077-92F expansion enclosure and
Storwize V5000 Gen2 system. If either of the two expansion canisters has a failure, the other expansion
canister assumes the full I/O load. Figure 96 on page 93 shows the features of an expansion enclosure.
Figure 96. Expansion canister
1
Canister fault indicator
2
Canister status
3
Canister power indicator
4
and
6
SAS link fault indicators
5
and
7
SAS link operational indicators
8
Canister release handles
Procedure
1. Read all safety information.
2. Locate the expansion canister to be removed.
3. Release the lower cable management arm to swing it out of the way, as described in “Moving the cable
4. Remove the SAS cables from the expansion canister, as described in “Removing and installing a SAS
5. Rotate the handles on the expansion canister outward, as shown in Figure 97 on page 94.
Chapter 2. Installing the system hardware 93
Summary of Contents for Storwize V5000 Gen 2 Series
Page 1: ...IBM Storwize V5000 Gen2 Quick Installation Guide IBM...
Page 5: ...Index 149 v...
Page 6: ...vi...
Page 156: ...130 Storwize V5000 Gen2 Quick Installation Guide...
Page 164: ...138 Storwize V5000 Gen2 Quick Installation Guide...
Page 166: ...140 Storwize V5000 Gen2 Quick Installation Guide...
Page 168: ...142 Storwize V5000 Gen2 Quick Installation Guide...
Page 177: ......
Page 178: ...IBM...