Removing a power supply: 2077-92F
You can remove either of the redundant power supply units in a 2077-92F expansion enclosure.
Redundant power supplies operate in parallel; one continues to provide power to the enclosure if the
other fails.
Before you begin
Important: You can remove a PSU without powering off the expansion enclosure. However, to maintain
operating temperature, ensure that you perform the following tasks.
• Do not remove a faulty PSU until its replacement is ready to be installed.
• Do not remove a PSU from an operational enclosure for more than approximately 10 minutes. The
reduction in airflow through the enclosure might cause the enclosure or its components to shut down to
protect from overheating.
About this task
Each PSU provides cooling to the lower part of the enclosure. Ensure that the second PSU in the enclosure
is powered on and operating correctly. For example, in Figure 86 on page 85, PSU 1 is operating while
PSU 2 is being removed.
Review and follow the procedures for handling static-sensitive devices before you remove the power
supply unit (PSU).
Procedure
1. Read all safety information.
2. Remove the 1U fascia that covers the PSUs on the front of the expansion enclosure, as described in
“Removing the fascia: 2077-92F ” on page 70.
3. Press on the handle lock to release the handles on the PSU.
4. Rotate the handles outward, as shown in Figure 86 on page 85.
Figure 86. Releasing the power supply handles
Chapter 2. Installing the system hardware 85
Summary of Contents for Storwize V5000 Gen 2 Series
Page 1: ...IBM Storwize V5000 Gen2 Quick Installation Guide IBM...
Page 5: ...Index 149 v...
Page 6: ...vi...
Page 156: ...130 Storwize V5000 Gen2 Quick Installation Guide...
Page 164: ...138 Storwize V5000 Gen2 Quick Installation Guide...
Page 166: ...140 Storwize V5000 Gen2 Quick Installation Guide...
Page 168: ...142 Storwize V5000 Gen2 Quick Installation Guide...
Page 177: ......
Page 178: ...IBM...