For Windows NT 4.0, use the following software to replace the controller. Follow the
on-screen directions:
v
IBM Netfinity PCI Hot Plug for Windows NT 4.0 Package, version 4.1 or later
v
(For the ServeRAID-4M, ServeRAID-4Mx, ServeRAID-4L, and ServeRAID-4Lx
controllers only) IBM PCI Hot Plug Adapter Update, version 1.0, for the IBM
Netfinity PCI Hot Plug for Windows NT 4.0
v
IBM ServeRAID Manager program
v
IBM ServeRAID Hot Replace Wizard
Recovering from a failed physical drive in a RAID level-5E environment
If a RAID level-5E logical drive undergoes compression as the result of a failed
physical drive, the failed drive will be marked defunct hot spare (DHS). Replace the
defunct physical drive or remove the defunct drive from the enclosure as soon as
possible. If a DHS drive is present, the RAID level-5E logical drive might not
failover.
Recovering from a power failure during a failover
If a power failure occurs during a failover, the two controllers in the active-passive
pair might have the following problems:
v
Some logical drives are configured on one controller and some logical drives are
configured on the other controller.
v
A logical drive does not appear on either controller.
Complete the following steps to recover from a power failure:
1. Run
ipssend merge
for every merge-group number configured on the active
controller.
Note:
If
ipssend
merge fails, run
ipssend merge partner
for every
merge-group number configured on the active controller.
2. Run
ipssend unmerge
for every merge-group number configured on the
passive controller.
3. Shut down and restart the server. Windows 2000 and Windows NT 4.0 pairs the
controllers again.
Troubleshooting an IBM ServeRAID Cluster Solution
There is the possibility that one of the servers, one of the ServeRAID controllers, or
one of the hard disk drives in a cluster might fail. This section presents procedures
you can take to recover from these potential problems. If you still have problems
after following these procedures, contact your IBM service representative for further
information. Also, you can find hints and tips to help you solve problems on the IBM
Support Web site. See “Downloadable files from the World Wide Web” on page 141
for additional information.
Recovering from a failed ServeRAID server
When replacing a failed server in a high-availability configuration, you might not
need to replace the ServeRAID controller. However, if you replace your ServeRAID
controller, you must reconfigure the controller after installing your new server.
166
IBM ServeRAID: User’s Reference, Version 5.10
Summary of Contents for ServeRAID
Page 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Page 10: ...x IBM ServeRAID User s Reference Version 5 10...
Page 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Page 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Page 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Page 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Page 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Page 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Page 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Page 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Page 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Page 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Page 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Page 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Page 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Page 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Page 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Page 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Page 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Page 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Page 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Page 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Page 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Page 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Page 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Page 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Page 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Page 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Page 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Page 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Page 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Page 225: ......
Page 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...