Table 6. Configuration and verification tasks (continued)
Task
Task details or additional information
Establishing an Ethernet connection to the
device.
Connect Ethernet cable to active CP blade
Ethernet port labeled "Management" and
establish a connection.
Set a unique domain ID for the device.
Disable the device using the
switchDisable
command, and then use the
configure
command to step through prompts to
configure a domain ID. Use
switchEnable
to
re-enable the device.
Set the date and time for the device.
Use the
date
,
tsTimeZone
, and
tsClockServer
commands to set date, time
zone, and synchronize local time of device
with NTP server.
Customize a switch and chassis name for the
device.
Use the
switchName
command, followed by
new name in quote marks (
switchname
"bigswitch".)
Use the
chassisName
command followed by
the new name in quote marks (
chassisname
"chassis_002").
Verify installed licenses and license key
Enter the
licenseShow
command to
determine display enabled licenses and the
license key.
Enter the
licenseIdShow
command to obtain
the chassis ID.
Record the license key and chassis ID for
future reference.
Verify correct operation of device.
Check LEDs on blades and FRUs, and use
the following commands to verify operation:
v
psShow
v
fanShow
v
switchShow
v
fabricShow
v
slotShow
v
tempShow
v
historyShow
v
errdump
Back up the configuration.
Use the
configUpload
command.
Items required
The following items are required for initial setup and verification of the device:
v
The device, mounted and installed with the required blades, FRUs, transceivers,
and cables and is connected to a power source.
v
A workstation computer with an installed terminal emulator application, such as
HyperTerminal for Windows.
v
An unused IP address with corresponding subnet mask and gateway address.
v
A serial cable (provided) with an RJ-45 connector.
v
An RJ-45 to DB-9 adapter.
38
SAN512B-6 Installation, Service, and User Guide
Summary of Contents for SAN512B-6
Page 2: ......
Page 8: ...vi SAN512B 6 Installation Service and User Guide...
Page 10: ...viii SAN512B 6 Installation Service and User Guide...
Page 12: ...x SAN512B 6 Installation Service and User Guide...
Page 40: ...16 SAN512B 6 Installation Service and User Guide...
Page 60: ...36 SAN512B 6 Installation Service and User Guide...
Page 128: ...104 SAN512B 6 Installation Service and User Guide...
Page 140: ...116 SAN512B 6 Installation Service and User Guide...
Page 170: ...146 SAN512B 6 Installation Service and User Guide...
Page 184: ...160 SAN512B 6 Installation Service and User Guide...
Page 196: ...172 SAN512B 6 Installation Service and User Guide...
Page 208: ...184 SAN512B 6 Installation Service and User Guide...
Page 258: ...234 SAN512B 6 Installation Service and User Guide...
Page 274: ...250 SAN512B 6 Installation Service and User Guide...
Page 285: ......
Page 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...