v
Crimping tool to crimp the grounding wire to the grounding lug.
v
Wire-stripping tool to remove the insulation from the grounding wire.
Starting the Switch
About this task
This section provides the following information.
v
Connecting the power supplies.
v
Powering up the switch and verifying component installation.
Note:
Hazardous voltage or energy is present on the backplane when the system is
operating. Use caution when servicing.
CAUTION:
During this procedure, wear grounding wrist straps to avoid ESD damage to the
switch.
To power up the switch and verify hardware operation, follow these steps.
1.
Verify that the power switches on all power supplies are off.
2.
Plug the power cable into the power supply and tighten the screw on the
power cable retainer to ensure that the cable cannot be pulled out.
3.
Verify that both power supplies and fan modules are installed and tighten any
loose captive screws.
Note:
Depending on the outlet receptacle on your power distribution unit, you
may need the optional jumper power cord to connect the IBM SAN50C-R
switch to your outlet receptacle.
4.
Connect the other end of the power cable to a power source.
5.
Ensure that the switch is adequately grounded and that the power cables are
connected to outlets that have the required AC power voltages.
Powering Up the Switch and Verifying Component Installation
About this task
Note:
Do not connect the MGMT 10/100 Ethernet port to the LAN until the initial
switch configuration has been performed. For instructions on configuring the
switch, see the IBM SAN50C-R Integrated Supervisor Module.
For instructions on connecting to the console port, see the “Connecting to the
Console Port” section on page 1-2.
Note:
Hazardous voltage or energy is present on the backplane when the system is
operating. Use caution when servicing.
CAUTION:
During this procedure, wear grounding wrist straps to avoid ESD damage to the
switch.
To power up the switch and verify hardware operation, follow these steps.
1.
Power on the switch by turning the power switches on the power supplies or
PEMs to the on (|) position. The switch boots automatically.
Chapter 2. Installing the IBM SAN50C-R switch
23
Summary of Contents for SAN50C-R
Page 1: ...IBM Storage Networking SAN50C R Installation Service and User Guide SC27 9274 00 IBM...
Page 2: ......
Page 3: ...IBM Storage Networking SAN50C R Installation Service and User Guide SC27 9274 00 IBM...
Page 8: ...vi SAN50C R Installation Service and User Guide...
Page 10: ...viii SAN50C R Installation Service and User Guide...
Page 24: ...xxii SAN50C R Installation Service and User Guide...
Page 31: ...rav00052 Figure 7 IBM SAN50C R Fan Module Chapter 1 Introducing the SAN50C R 7...
Page 52: ...28 SAN50C R Installation Service and User Guide...
Page 60: ...36 SAN50C R Installation Service and User Guide...
Page 72: ...48 SAN50C R Installation Service and User Guide...
Page 74: ...50 SAN50C R Installation Service and User Guide...
Page 84: ...60 SAN50C R Installation Service and User Guide...
Page 85: ......