6
10 Gbps Ethernet port 2
7
Power connector 1
8
Power connector 2
9
Serial port for UPS communications (RS232)
10
1 Gbps Ethernet port 2
11
1 Gbps Ethernet port 1
This service action assumes that you have removed the top cover and that:
v
The node is off.
v
The power cables are disconnected.
v
The data cables are disconnected.
To replace the SAN Volume Controller 2145-CG8 10 Gbps Ethernet riser-card assembly, perform the
following steps:
1.
If present, remove both Ethernet small form-factor pluggable (SFP) transceivers before replacing the
Ethernet riser-card assembly, as described in “Removing and replacing an Ethernet SFP transceiver”
on page 189.
2.
Grasp each end of the Ethernet riser-card assembly, tilt the Ethernet riser-card assembly so that the
side with the PCI riser card is higher than the opposite side, and the back is higher than the front.
3.
Locate the cage that houses the Ethernet SFP transceivers through the hole in the back of the node.
4.
Align the 10 Gbps Ethernet riser-card assembly connector with the PCI slot 2 connector on the system
board, as shown in Figure 192.
1
PCI slot 2 riser-card connector
2
10 Gbps Ethernet riser-card assembly
When looking from the back, the PCI slot 1 connector is the connector on the left. The 10 Gbps
Ethernet riser-card assembly attaches to the PCI slot 2 connector on the right side of the system board,
when looking from the back.
5.
Press down on the top of the Ethernet riser-card assembly until the card settles in the slot.
6.
Anchor the Ethernet riser-card assembly using two fastening screws from the back of the node, as
shown in the cutaway view of a section of the rail in Figure 193 on page 196.
svc00253b
2
1
Figure 192. Replacing the 10 Gbps Ethernet riser-card assembly for the SAN Volume Controller 2145-CG8
Chapter 2. Removing and replacing parts
195
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...