Up to three electrical Ethernet cables can be connected to the SAN Volume Controller 2145-SV1 . The
cable connection table indicates the number of cables to connect. Connect to the ports in numerical
order, beginning with Ethernet port 1.
Procedure
To connect the SAN Volume Controller 2145-SV1 to the SAN and to the Ethernet network, complete the
following steps.
1. Connect the Ethernet cables to the Ethernet ports on the rear of the SAN Volume Controller 2145-
SV1 .
Ports 1-3 are standard. If you have 10 Gbps or 25 Gbps Optical Ethernet adapters that you want to
connect to an Ethernet switch for iSCSI communications, 11 Ethernet ports might be available. Figure
31 on page 27 shows one of the possible node configurations.
Figure 31. Ethernet ports on the rear of the SAN Volume Controller 2145-SV1
1
-
3
10 Gbps Ethernet ports 1-3
4
-
7
10 Gbps optical Ethernet ports 4-7
2. Connect the other end of the Ethernet cable to the proper connector on the Ethernet hub or switch.
3. Optional: If the Fibre Channel feature is installed, you can connect Fibre Channel cables to the Fibre
Channel ports as required by your configuration.
Figure 32 on page 27 shows an example of the device with 16 Gbps Fibre Channel adapters that are
installed in slots 3, 4, and 6. A 10 Gbps Optical Ethernet adapter is used for Fibre Channel over
Ethernet (FCoE) communications and is installed in slot 7, providing additional Fibre Channel ports.
Figure 32. Fibre Channel ports
1
-
16
Fibre Channel ports 1-16
Note: If you are installing a hot-spare node, the Fibre Channel cabling must be identical for all nodes
of the system. In other words, port 1 on every node must be connected to the same fabric, port 2 on
every node must be connected to the same fabric, and so on.
Chapter 2. Installing the SAN Volume Controller 2145-SV1 hardware 27
Summary of Contents for SAN Volume Controller 2145-12F
Page 1: ...IBM SAN Volume Controller Hardware Installation Guide IBM...
Page 6: ...vi...
Page 48: ...16 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 62: ...30 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...40 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 168: ...136 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 176: ...144 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 178: ...146 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 182: ...150 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 193: ......
Page 194: ...IBM...