Replacing a power supply in the 8335-GCA or 8335-GTA
To replace a power supply in the system, complete the steps in this procedure.
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Align the power supply (A) with the bay and slide the power supply into the system until the
terracotta latch (B) locks in place. See Figure 77.
3.
Connect and fasten the power cord to the power supply.
a.
Connect the power cord to the power supply. See Figure 78 on page 109.
b.
Use the hook-and-loop fastener and tie the power cord to the power supply handle. To properly
loop the power cables, see “Connecting the power cords to an 8335-GCA or 8335-GTA system” on
page 104
Attention:
This system is equipped with two power supplies. Before you continue with this
procedure, connect all power cords to the power supplies and strap them.
Figure 76. Removing a power supply from the system
Figure 77. Replacing a power supply in the system
108
Installing the System and Ordered Parts for the 8335-GCA or 8335-GTA
Summary of Contents for S822LC
Page 2: ......
Page 16: ...xiv Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 104: ...88 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 122: ...106 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 125: ...Figure 78 Connecting the power cord to the power supply Power supplies 109...
Page 126: ...110 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 138: ...122 Installing the System and Ordered Parts for the 8335 GCA or 8335 GTA...
Page 139: ......
Page 140: ...IBM Printed in USA...