7-2
Intelligent Battery Backup Unit Specifications
7.2
Battery Life and Data Retention Time
The MegaRAID configuration utilities display a counter showing the
number of times the iBBU has been recharged. When you install a new
iBBU, the battery recharge cycle counter for the iBBU is automatically set
to zero. For instructions on installing the iBBU, see
“Installing the iBBU on the ServeRAID-MR10M Controller.”
For optimal performance, replace the battery backup unit once a year.
The data retention time shown in
is approximate. They can
vary based on a number of factors, including the following:
•
Capacity of the battery pack and the battery load
•
Ambient temperature
•
Battery age and the number of discharge cycles
•
Number of DIMMs installed and the number of chips on the DIMMs
•
DRAM size
Battery Fast Charge Time
~3 hours
Socket Type
N/A
Module Support
DDR2
Cache Memory Size Supported
128 MB - 512 MB
Memory Bus Speed
667 MHz
Memory Bus Width
Maximum 72 bit
Error Correcting Capability (ECC)
N/A
Auxiliary
Yes
Table 7.1
Intelligent Battery Backup Unit Specifications
iBBU
Table 7.2
Reference Data Retention Times
BBU
Name
Data Retention Times
iBBU
- 72 hours for 512 Mbytes, using five 64 Mx16 parts DDR2 (low power)
- 72 hours for 256 Mbytes, using five 32 Mx16 parts DDR2 (low power)
- 72 hours for 128 Mbytes, using five 16 Mx16 parts DDR2 (low power)
Summary of Contents for Redbooks ServeRAID-MR10M
Page 1: ...IBM P N 81Y1995 ServeRAID MR10M USER S GUIDE J u n e 2 0 1 0...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 34: ...1 18 Overview...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 74: ...6 16 Using the Intelligent Battery Backup Unit...
Page 80: ...A 4 Notices...
Page 86: ...B 6 Glossary of Terms and Abbreviations...
Page 87: ......
Page 88: ...81Y1995...