2-2
ServeRAID-MR10i SAS/SATA Controller Hardware Installation
2.2
Quick Installation
The following steps are for quick ServeRAID-MR10i controller
installation. These steps are for experienced computer users/installers.
Section 2.3, “Detailed Installation,”
contains the steps for all others to
follow.
Step 1. Review all safety information provided with the server. Turn off
the server and all attached devices, and unplug the server and
the device power cords.
Step 2. Open the cabinet of the host system by following the
instructions in the host system technical documentation.
Step 3. Check the intelligent Battery Backup Unit (iBBU) on the
controller.
Step 4. Install the ServeRAID-MR10i controller in the computer and
connect the SAS devices or SATA II devices to it. Make sure
that the cables you use conform to all specifications.
Step 5. Perform a safety check.
a. Make sure that all cables are properly attached
b. Make sure that the ServeRAID-MR10i controller is installed
correctly
c. Close the cabinet of the host system
Step 6. Reconnect the power cords to the system and to all of the
attached devices.
Step 7. Turn on the power to the system after you complete the safety
check.
2.3
Detailed Installation
This section provides detailed instructions for installing a ServeRAID-
MR10i controller.
Step 1. Unpack the ServeRAID-MR10i Controller
Unpack and remove the ServeRAID-MR10i controller. Inspect
it for damage. If it appears damaged, or if any of the following
Summary of Contents for Redbooks ServeRAID-MR10i
Page 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 78: ...A 4 Notices...
Page 84: ...B 6 Glossary of Terms and Abbreviations...
Page 85: ......
Page 86: ...4 6 M1 3 7 7...