A1xxyyyy service processor SRCs
An A1xxyyyy system reference code (SRC) is an attention code that offers information about a platform
or service processor dump or confirms a control panel function request. Take the steps in the Action
column only if the BladeSystem appears to hang on an attention code.
Table 9 shows A1xxyyyy SRCs.
Table 9. A1xxyyyy service processor SRCs
Attention code
Description
Action
A1xxyyyy
Attention code
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system board and chassis
assembly, as described in “Replacing the
FRU system-board and chassis assembly” on
page 260.
A2xxyyyy Logical partition SRCs
An A2xxyyyy SRC is a logical partition reference code that is related to logical partitioning.
Table 10. A2xxyyyy Logical partition SRCs
Reference Code
Description
Action
A2xxyyyy
See the description for the B200yyyy error
code with the same
yyyy
value.
Perform the action described in the B200yyyy
error code with the same
yyyy
value.
A2D03000
User-initiated immediate termination and MSD
of a partition.
No corrective action is required.
A2D03001
User-initiated RSCDUMP of RPA partition's
PFW content.
No corrective action is required.
A2D03002
User-initiated RSCDUMP of IBM i partition's
SLIC bootloader and PFW content.
No corrective action is required.
A700yyyy Licensed internal code SRCs
An A700xxxx system reference code (SRC) is an error/event code that is related to licensed internal code.
Table 11. A700yyyy Licensed internal code SRCs
Reference Code
Description
Action
A700173C
Informational system log entry only.
No corrective action is required.
A7003000
A user-initiated platform dump occurred.
No service action required.
A7004700
Informational system log entry only.
No corrective action is required.
A7004712
A problem occurred when initializing, reading,
or using system VPD.
Replace the management card, as described in
“Removing the tier 2 management card” on
page 255 and “Installing the tier 2 management
card” on page 256.
A7004713
A problem occurred when initializing, reading,
or using system VPD.
Replace the management card, as described in
“Removing the tier 2 management card” on
page 255 and “Installing the tier 2 management
card” on page 256.
A7004715
A problem occurred when initializing, reading,
or using system VPD.
Replace the management card, as described in
“Removing the tier 2 management card” on
page 255 and “Installing the tier 2 management
card” on page 256.
24
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)