Location codes
Location codes identify components of the blade server. Location codes are displayed with some error
codes to identify the blade server component that is causing the error.
See “System-board connectors” on page 8 for component locations.
Notes:
1.
Location codes do not indicate the location of the blade server within the BladeCenter unit. The codes
identify components of the blade server only.
2.
For checkpoints with no associated location code, see “Light path diagnostics” on page 214 to identify
the failing component when there is a hang condition.
3.
For checkpoints with location codes, use the following table to identify the failing component when
there is a hang condition.
4.
For 8-digit codes not listed in Table 4, see the “Checkout procedure” on page 184.
Table 4. Location codes
Components
Physical Location Code
CRU LED
U
n
location codes are for enclosure and VPD locations.
U
n
= Utttt.mmm.sssssss
tttt = system machine type
mmm = system model number
sssssss = system serial number
DIMM 1
Un-P1-C1
Yes
DIMM 2
Un-P1-C2
Yes
DIMM 3
Un-P1-C3
Yes
DIMM 4
Un-P1-C4
Yes
DIMM 5
Un-P1-C5
Yes
DIMM 6
Un-P1-C6
Yes
DIMM 7
Un-P1-C7
Yes
DIMM 8
Un-P1-C8
Yes
2.5" SAS HDD1
Un-P1-D1
Yes
2.5" SAS HDD2
Un-P1-D2
Yes
Management Card
Un-P1-C9
Yes
Battery
Un-P1-E1
Yes
PCIe High Speed Expansion Card
Un-P1-C12
Yes
1Xe Card
Un-P1-C11
Yes
USB Port 1 (CDROM/FDD)
Un-P1-T1
No
USB Port 2 (CDROM/FDD)
Un-P1-T2
No
SAS controller
Un-P1-T3
No
Ethernet HEA0_A
Un-P1-T4
No
Ethernet HEA0_B
Un-P1-T5
No
Machine Location Code
Utttt.mmm.sssssss
No
Um codes are for firmware. The format is the same as for a Un location code.
Um = Utttt.mmm.sssssss
14
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)