background image

If you are viewing this information in softcopy, the photographs and color illustrations may not appear.
The drawings and specifications contained herein shall not be reproduced in whole or in part without the

written permission of IBM.
IBM has prepared this information for use with the specific machines indicated. IBM makes no

representations that it is suitable for any other purpose.
IBM's computer systems contain mechanisms designed to reduce the possibility of undetected data

corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages,

system failures, power fluctuations or outages, or component failures must verify the accuracy of

operations performed and data saved or transmitted by the system at or near the time of the outage or

failure. In addition, users must establish procedures to ensure that there is independent data verification

before relying on such data in sensitive or critical operations. Users should periodically check IBM's

support websites for updated information and fixes applicable to the system and related software.

Homologation statement

This product may not be certified in your country for connection by any means whatsoever to interfaces

of public telecommunications networks. Further certification may be required by law prior to making any

such connection. Contact an IBM representative or reseller for any questions.

Accessibility features for IBM Power servers

Accessibility features assist users who have a disability, such as restricted mobility or limited vision, to

use information technology content successfully.

Overview

The IBM Power servers include the following major accessibility features:
• Keyboard-only operation
• Operations that use a screen reader
The IBM Power servers use the latest W3C Standard, WAI-ARIA 1.0 (www.w3.org/TR/wai-aria/),

to ensure compliance with ICT Accessibility 508 Standards and 255 Guidelines (https://www.access-

board.gov/ict/) and Web Content Accessibility Guidelines (WCAG) 2.0 (www.w3.org/TR/WCAG20/). To

take advantage of accessibility features, use the latest release of your screen reader and the latest web

browser that is supported by the IBM Power servers.
The IBM Power servers online product documentation in IBM Documentation is enabled for accessibility.

For more information about IBM's commitment to accessibility, see the IBM accessibility website at IBM

Accessibility (https://www.ibm.com/able/).

Keyboard navigation

This product uses standard navigation keys.

Interface information

The IBM Power servers user interfaces do not have content that flashes 2 - 55 times per second.
The IBM Power servers web user interface relies on cascading style sheets to render content properly and

to provide a usable experience. The application provides an equivalent way for low-vision users to use

system display settings, including high-contrast mode. You can control font size by using the device or

web browser settings.
The IBM Power servers web user interface includes WAI-ARIA navigational landmarks that you can use to

quickly navigate to functional areas in the application.

14  Power Systems: Installing the IBM Power S1014 (9105-41B)

Summary of Contents for Power S1014

Page 1: ...Power Systems Installing the IBM Power S1014 9105 41B IBM GI11 0002 00...

Page 2: ...1110 and G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER10 processor and to all associated models Copyrig...

Page 3: ...server to the installation site 1 Completing inventory for your stand alone server 1 Cabling the server and setting up a console 2 Completing the server setup 9 Notices 13 Accessibility features for...

Page 4: ...iv...

Page 5: ...erordnung geeignet Laser safety information IBM servers can use I O cards or features that are fiber optic based and that utilize lasers or LEDs Laser compliance IBM servers may be installed inside or...

Page 6: ...power attach the power cords to the outlets 5 For racks with a DC power distribution panel PDP restore the power from the Customer s DC power source and turn on the circuit breakers located in the PDP...

Page 7: ...g or overcurrent protection To provide the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply cir...

Page 8: ...ned at more than 10 degrees When the rack cabinet is in the new location complete the following steps Lower the four leveling pads Install stabilizer brackets on the rack cabinet or in an earthquake e...

Page 9: ...sition read the installation instructions Do not put any load on the slide rail mounted equipment mounted in the installation position Do not leave the slide rail mounted equipment in the installation...

Page 10: ...power cords and power cables L003 L007 CAUTION A hot surface nearby L007 L008 CAUTION Hazardous moving parts nearby L008 L018 or CAUTION High levels of acoustical noise are or could be under certain c...

Page 11: ...exposure C026 CAUTION Data processing environments can contain equipment transmitting on system links with laser modules that operate at greater than Class 1 power levels For this reason never look i...

Page 12: ...tended platform Only raise load if properly centered on platform Do not place more than 200 lb 91 kg on edge of sliding platform shelf also considering the load s center of mass gravity CoG Do not cor...

Page 13: ...ing System GR 1089 CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS Network Equipment Building System GR 1089 CORE The equipment is suitable for ins...

Page 14: ...xiv Power Systems Installing the IBM Power S1014 9105 41B...

Page 15: ...ates and fixes see the Hardware Management Console Support and downloads website https www14 software ibm com webapp set2 sas f hmcl home html Consider the following prerequisites before you install t...

Page 16: ...ntenance and control The eBMC also provides access to the system event log files SEL The eBMC is a specialized service processor that monitors the physical state of the system by using sensors A syste...

Page 17: ...page 6 Keyboard video and mouse KVM Linux or VIOS Yes Monitor and USB cables equipped with KVM Cabling the server with keyboard video and mouse on page 5 Cabling the server with an ASCII terminal If...

Page 18: ...e power supplies are flashing If none of the indicators are flashing check the power cord connections 3 Wait for the green light on the control panel to start flashing 4 Ensure that your ASCII termina...

Page 19: ...com support knowledgecenter POWER9 p10hai p10hai_netconhmc htm Notes You can also have multiple systems that are attached to a switch that is then connected to the HMC For instructions see HMC networ...

Page 20: ...M i Access ACS Getting Started https www ibm com support pages ibm i access acs getting started 3 0 Note It is recommended that you log onto the PC as the local administrator This ensures that you hav...

Page 21: ...e server set to a manual IPL push the white power button to power on the server Note During the IPL the system displays C6004031 on the control panel which indicates that the system is searching for a...

Page 22: ...the information to be displayed 8 To set a static IP address for the Operations Console complete the following steps a Sign on with QSECOFR The default password is QSECOFR and it is case sensitive b A...

Page 23: ...the following steps i Connect the system power cords from the server and I O drawers to the PDU with an IEC 320 type receptacle ii Attach the PDU input power cord and plug it into the power source ii...

Page 24: ...date the time of day on the managed system by using the Advanced System Management Interface ASMI To access ASMI by using the HMC complete the following steps a In the contents area select the managed...

Page 25: ...edgecenter POWER10 p10hdx p10hdx_installlinux htm Install the VIOS operating system For instructions see Installing VIOS https www ibm com support knowledgecenter POWER10 p10hb1 p10hb1_vios_install ht...

Page 26: ...the operating system Install the AIX operating system For instructions see Installing AIX http www ibm com support knowledgecenter POWER10 p10hdx p10hdx_installaix htm Install the Linux operating sys...

Page 27: ...oduct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner...

Page 28: ...st users who have a disability such as restricted mobility or limited vision to use information technology content successfully Overview The IBM Power servers include the following major accessibility...

Page 29: ...deployed for this Software Offering provide you as the customer the ability to collect personally identifiable information from end users via cookies and other technologies you should seek your own le...

Page 30: ...nforderungen der EU Richtlinie 2014 30 EU zur Angleichung der Rechtsvorschriften ber die elektromagnetische Vertr glichkeit in den EU Mitgliedsstaatenund h lt die Grenzwerte der EN 55022 EN 55032 Klas...

Page 31: ...ormationen Das Ger t erf llt die Schutzanforderungen nach EN 55024 und EN 55022 EN 55032 Klasse A Japan Electronics and Information Technology Industries Association JEITA Notice This statement applie...

Page 32: ...ssion FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Page 33: ...to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts Class B Notices The following Class B statements apply to features designated as electro...

Page 34: ...ormit tszeichen CE zu f hren Verantwortlich f r die Einhaltung der EMV Vorschriften ist der Hersteller International Business Machines Corp New Orchard Road Armonk New York 10504 Tel 914 499 1900 Der...

Page 35: ...by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Page 36: ...ay these publications or any portion thereof outside your enterprise without the express consent of IBM Rights Except as expressly granted in this permission no other permissions licenses or rights ar...

Page 37: ......

Page 38: ...IBM Part Number 03KG354 GI11 0002 00 1P P N 03KG354...

Reviews: