17.
Select and highlight the service action event from the Error Associated With This Serviceable Event
window.
18.
Click Close Event.
19.
Add comments for the serviceable event. Include any unique additional information. Click OK. The
following steps will add or update FRU information.
20.
Did you replace, add, or modify a FRU of the open service action event?
v
Yes:
Continue with the next step.
v
No:
Go to step 22.
21.
From the FRU list, select a FRU that you need to update. Double-click the FRU, and update the FRU
information. Go to step 23.
22.
Select the No FRU Replaced for this Serviceable Event option.
23.
Click OK to close the service action event.
24.
Is the list of all partitions you recorded in step 11 on page 83 empty?
v
Yes:
Go to step 32.
v
No:
Continue with the next step.
25.
Does the list of all partitions you recorded in step 11 on page 83 contain more than one entry?
v
Yes:
Continue with the next step.
v
No:
Go to step 32.
26.
Is the error class recorded in step 25 AIX?
v
Yes:
Continue with the next step.
v
No:
Go to step 32.
27.
Perform all the following steps for each entry in the list of all partitions you recorded in step 11 on
page 83, except for the partition you were using to debug the original problem.
28.
From the list of all partitions, open the HMC virtual terminal window of a partition, and then type
diag
at the AIX command prompt.
29.
When the diagnostic operating instructions are displayed, complete the following steps:
a.
Press Enter.
b.
Select the Task Selection option.
c.
Select the Log Repair option.
d.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the resource associated with that
repair action.
v
If the resource associated with your repair action is not displayed on the Resource List, select
sysplanar0
.
e.
Click Commit after you make your selection.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
30.
Exit from diagnostics in this partition and return to the AIX command prompt.
31.
Have all the partitions in the list of all the partitions you recorded in step 11 on page 83 been
processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 24 to process the next partition in the list you recorded in step 11 on page 83.
32.
Have all the serviceable events recorded in step 4 on page 83 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 5 on page 83 and process the next service action event in the list of serviceable
events recorded in step 4 on page 83.
33.
While processing all service action events, were you directed to step 14 on page 83?
84
PCIe3 x8 SAS RAID internal adapter 6 Gb
Summary of Contents for PCIe3 x8 SAS RAID internal adapter 6 Gb
Page 2: ......
Page 8: ...vi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 18: ...xvi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 36: ...18 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 118: ...100 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 129: ...Notices 111 ...
Page 130: ...IBM Printed in USA ...