CoD VET Information
System type: 7895
System serial number: 12-34567
Anchor card CCIN: 52EF
Anchor card serial number: 01-231S000
Anchor card unique identifier: 30250812077C3228
Resource ID: CA1F
Activated Resources: 0000
Sequence number: 0040
Entry check: EC
Go to step 3.
v
By using Integrated Virtualization Manager (IVM):
a.
Start the IVM, if it is not running already.
b.
In an IVM session, enter the
lsvet -t code
command.
The following is an example of the
lsvet
command output:
Note:
When you request the activation code, you must supply the information that is
emphasized in the following example.
sys_type=7895,sys_serial_num=12-34567,anchor_card_ccin=52EF,
anchor_card_serial_num=01-231S000, anchor_card_unique_id=30250812077C3228,
resource_id=CA1F,activated_resources=0000,sequence_num=0040, entry_check=EC
Go to step 3.
3.
Send a request for the VET activation code for your replacement management card to the System p
Capacity on Demand mailbox at [email protected].
If the ASMI was used to get the VET information, include the following fields and their values:
v
System type
v
System serial number
v
Card type
v
Card serial number
v
Card ID
If the HMC or FSM was used to get the VET information, include the following fields and their
values:
v
System type
v
System serial number
v
Anchor card CCIN
v
Anchor card serial number
v
Anchor card unique identifier
If the IVM
lsvet -t code
command was used to get the VET information, include the following fields
and their values:
v
sys_type
v
sys_serial_num
v
anchor_card_ccin
v
anchor_card_serial_num
v
anchor_card_unique_id
Following is an example of a statement that you can include in the email:
Provide a VET activation code for the new
management card (anchor card) in my Flex power compute node.
The System p Capacity on Demand site then generates the code and posts the VET activation code on
the website.
4.
Go to the Capacity on Demand Activation code web page to retrieve your code.
Chapter 6. Installing and removing components
79
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...