IBM Nways 3746-900 External Cable References Download Page 30

 

LIC11 Cable Reference

 

 

LIC11 Cable List

Table

3-7. LIC11 Low/Medium-Speed Line Attachment Cables

Cable Part Number

Feature
Code

Length
Meters (Feet)

World Wide

World Wide
Except Canada

58G5601  (1)
17G5915  (2)
58G5602
17G5916  (2)
58G5603
17G5917  (2)
58G5604
17G5918  (2)
58G5605
17G5919  (2)
58G5606

58G5705 (1)
58G5717 (2)
58G5706
58G5718 (2)
58G5707
58G5719 (2)
58G5708
58G5720 (2)
58G5709
58G5721 (2)
58G5710

9913 (1)
9715 (3)
9714 (3)
9717 (3)
9716 (3)
5219
5218
5221
5220
5223
5222

1.3 (4)
7  (23)
7  (23)
15  (50)
15  (50)
35  (115)
35  (115)
70  (230)
70  (230)
105 (345)
105 (345)

Notes:

1. Cable from LIC11 to LCBB installed in the 3746-900 frame and identified by a

'specify code'.

2. Plenum Cable for U.S and Canada only.

3. This code is a specify code.

3-8

3746-9X0: ECR 

 

Summary of Contents for Nways 3746-900

Page 1: ...3746 Nways Multiprotocol Controller Models 900 and 950 IBM External Cable References SY33 2117 01...

Page 2: ......

Page 3: ...3746 Nways Multiprotocol Controller Models 900 and 950 IBM External Cable References SY33 2117 01...

Page 4: ...readers comments appears at the back of this publication If the form has been removed address your comments to IBM France Centre d Etudes et Recherches Service 0798 BP 79 06610 La Gaude France FAX 33...

Page 5: ...ction Box EBCB to the Ethernet Bridge 2 1 Controller Expansion Grounding 2 2 Grounding of LCB Via a Cable 2 3 Controller Expansion Unit Power Cables 2 4 Chapter 3 External Cables for 3746 Models 900 a...

Page 6: ...cuits 3 35 ARC Cable X 21 Attachement Transfix 3 36 Interchange Circuits 3 36 ARC Cable V 24 Attachement to DTE 3745 3 37 Interchange Circuits 3 37 ARC Cable V 24 Attachement to DCE 3745 3 38 Intercha...

Page 7: ...1 Part Number 58X9354 3 58 LIC16 3 59 LIC16 Wrap Plug 3 59 LIC16 E1 Cable 3 60 LIC16 E1 Cable List 3 60 Homologation and Notes 3 61 Appendix A Bibliography A 1 Customer Documentation for the 3745 Mode...

Page 8: ...vi 3746 9X0 ECR...

Page 9: ...fety Notices for United Kingdom 1 The IBM 3746 Expansion Unit Model 900 and IBM 3746 Nways Multiprotocol Controller Model 950 are manufactured according to the International Safety Standard EN 60950 a...

Page 10: ...ll requirements of the Canadian Interference Causing Equipment Regulations Avis de conformit aux normes d Industrie Canada Cet appareil num rique de la classe A respecte toutes les exigences du R glem...

Page 11: ...ion are trade marks or service marks of IBM Corporation in the United States or other countries The following terms denoted by a double asterisk used in this publication are trademarks of other compan...

Page 12: ...x 3746 9X0 ECR...

Page 13: ...950 This manual is also useful to all those who will prepare the site for the setup of the controller or during setup How This Manual Is Organized Chapter 1 Presents the service processor and RSF cabl...

Page 14: ...xii 3746 9X0 ECR...

Page 15: ...r Network Node Processor Modem From Integrated Modem 1 3 3 2 4 5 6 8 2 2 8 Optical Disk CD ROM or Figure 1 1 Service Processor and Network Node Processor Cables for 3746 900 Notes 1 For cable 1 refer...

Page 16: ...odem 1 3 3 2 4 5 6 8 2 2 8 Optical Disk CD ROM or Figure 1 2 Service Processor and Network Node Processor Cables for 3746 950 Notes 1 For cable 1 refer to Cable From the 3746 900 950 or any 3745 model...

Page 17: ...Cap Pin 5 Pin 9 Pin 1 Pin 6 3 4 5 2 Figure 1 3 LAN Cable Interchange Circuits See Interchange Circuit for Standard LAN Cable on page 3 3 Table 1 1 Cable from a 3746 900 or any 3745 model A to a 8228 C...

Page 18: ...Service Processor and Network Node Processor Cables 1 4 3746 9X0 ECR...

Page 19: ...ence 1 and Figure 3 4 on page 3 3 for details Table 2 1 Cable from a 3746 900 or any 3745 model A to a 8228 Cable Type Length m ft Cable Group Cable Part Number Standard Fixed 9 m 30 Shipped 76F9441 C...

Page 20: ...ground wire provided by IBM Controller Expansion A B To Permanent Connection of Building Ground Protective Earthing Figure 2 2 Ground Wire Connection on Controller Expansion A B Screw part number 61F...

Page 21: ...to ensure this connection Refer to Figure 2 3 Figure 2 3 LCB Grounding via Ground Wire IBM does not provide this wire In order to insure a good grounding this ground wire must made using a wire AWG 12...

Page 22: ...to the ac outlet distribution box Figure 2 5 Controller Expansion ac Outlet Distribution Box Figure 2 6 Power Cable for Units Connected to the ac Outlet Distribution Box Table 2 4 Power Cable for Unit...

Page 23: ...ote 1 Length to be specified on purchase order Table 3 2 Cable Length Ordering Information for EMEA Cable PN Feature Code Length Meters Feet 74F5412 74F5413 74F5414 74F5415 74F5416 74F9718 74F5417 74F...

Page 24: ...h Meters Feet 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 14F3797 5501 5502 5501 5502 5501 5502 5501 5502 5501 5502 5501 5502 5501 5502 5501 5502 5501 5502...

Page 25: ...t Wire Nbr Wire Color Connector 1 Position Connector 2 Position 1 2 3 4 5 SHIELD ORN BLACK RED GREEN GND 9 5 1 6 SHIELD ORN BLACK RED GREEN Table 3 5 Cable Length Ordering Information for EMEA Cable P...

Page 26: ...e Code Length Meters Feet 72F1236 72F1242 72F1236 72F1242 72F1236 72F1242 5601 5601 5601 5601 5601 5601 22 70 Fixed length 22 70 Plenum Fixed length 22 70 max Custom length 22 70 max Plenum Custom len...

Page 27: ...tandard pin layout Figure 3 5 Twisted Pair Connector Token Ring UTP Media Filter The Token Ring UTP media filter part number 43G3875 links a 4 and 16Mbps token ring network using UTP cabling Figure 3...

Page 28: ...30 ports with X 21 V 35 and V 24 EIA 232 interfaces Speeds Maximum port speed on an LCB is 256 kbps LIC11 Wrap Plug 1 6 11 5 10 15 Figure 3 7 LIC11 Wrap Plug Part Number 58G9425 3 9 o o Resistor Resi...

Page 29: ...8 o 8 R Data 4 o 8 o 4 48 VR 9 o 8 o 9 48 VR 5 o 8 o 5 Presence 11 o 8 o 11 Ground 1 o o 12 o 8 o 12 48 VE 13 o 8 o 13 48 VE 14 o 8 o 14 48 VB 15 o 8 o 15 48 VB Legend 8 A twisted pair 8 Figure 3 9 In...

Page 30: ...8 2 58G5605 17G5919 2 58G5606 58G5705 1 58G5717 2 58G5706 58G5718 2 58G5707 58G5719 2 58G5708 58G5720 2 58G5709 58G5721 2 58G5710 9913 1 9715 3 9714 3 9717 3 9716 3 5219 5218 5221 5220 5223 5222 1 3 4...

Page 31: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 From Conn Pos To Conn Pos spare spare spare spare spare spare spare spare sp...

Page 32: ...LCBB Cable Reference 15 1 31 44 30 16 44 30 15 31 16 1 IBM Figure 3 12 LCBB to LCBE Cable 3 10 3746 9X0 ECR...

Page 33: ...950 ARC model A ARC with an attached cable refer to Active Remote Connector ARC Assembly A on page 3 12 ARC model B ARC with a detachable cable refer to Active Remote Connector Assembly B and Cables L...

Page 34: ...5 16 15 50 61F4529 61F4529 ARC 3745 V 24 DTE see Note 3 ARC1D NLP 5 16 61F4525 ARC 3745 V 24 DCE see Note 3 ARC1C 6485 5 16 61F4525 ARC 3745 V 35 DTE see Note 3 ARC3D NLP 5 16 61F4578 ARC 3745 V 35 DC...

Page 35: ...1 2 3 4 4 5 6 7 8 8 9 10 XMIT DATA RCVE DATA DSRWRAP REQ TO SEND RFS CARRIER DETECTOR DTR TI CLKWRAP XMIT CLOCK RCVE CLOCK S GND DTR DSR 2 3 25 4 5 8 14 15 17 7 6 20 1 14 2 5 13 Figure 3 14 ARC Cable...

Page 36: ...CK S GND RCVE CLOCK RCVE DATA XMIT DATA CALL INDIC DATA SET READY R F S TEST INDICATOR CARRIER DETECTOR LOCAL LOOP BACK DATA TERM READY DATA RATE SEL REQ TO SEND NEW SYNCH REM LOOP BACK 15 7 17 3 2 22...

Page 37: ...8 19 104 RA 104 RB 115 RCLK A 115 RCLK B 114 TCLK A 114 TCLK B 103 TA 103 TB TCLKWRAP TCLKWRAP RCLWRAP RCLWRAP 109 RLSD 102 GND 105 RTS 106 RFS 107 DSR TI DSRWRAP DTR DSR R T V X Y AA P S HH KK LL JJ...

Page 38: ...104 RA 104 RB 115 RCLK A 115 RCLK B 114 TCLK A 114 TCLK B 103 TA 103 TB CLKWRAP CLKWRAP 106 RSF 142 T1 141 RLOOP 109 RLSD 140 MODEM TEST 102 GND 106 RT3 108 DTR 107 DSR R T V X Y AA P S HH KK O NN K...

Page 39: ...T1 2 T2 3 T3 4 T4 5 T5 6 T6 7 T7 RA R RB R IA I IB I SA S SB S TA T TB T CA C CB C XA XB GND IDI 4 11 5 12 6 13 2 9 3 10 7 14 8 15 8 15 1 9 Figure 3 22 ARC Cable X 21 Direct Attachment ARC4B 1 1 2 2 3...

Page 40: ...ector Position 1 T1 2 T2 3 T3 4 T4 5 T5 6 T6 7 T7 RA R RB R IA I IB I SA S SB S TA T TB T CA C CB C XA XB GND IDI 4 11 5 12 6 13 2 9 3 10 7 14 8 15 1 9 8 15 Figure 3 24 ARC Cable X 21 DCE ARC4A1 and A...

Page 41: ...l Name Connector Position 1 T1 2 T2 3 T3 4 T4 5 T5 RA R RB R SA S SB S TA T TB T XA XB GND IDI 4 11 6 13 2 9 7 14 8 15 1 9 8 15 Figure 3 26 ARC Cable X 21 DCE ARC4A3 and ARC4A4 1 1 2 2 3 4 5 6 7 8 9 1...

Page 42: ...Number Signal Name Connector Position 1 2 3 4 5 6 7 8 9 10 11 12 13 XMIT DATA RCVE DATA REQ TO SEND R F S DSR DTR NEW SYNCH XMIT CLOCK RCVE CLOCK S GND ID 0 ID 1 ID 2 14 16 18 17 20 2 9 22 25 7 and 15...

Page 43: ...ID 1 RCVE DATA ID 2 DATA SET READY CALL INDICATOR CLEAR TO SEND TEST INDICATOR CARRIER DETECTOR LOCAL LOOP BACK DATA TERM READY DATA RATE SEL REQ TO SENDTOR NEW SYNCH 22 7 and 15 25 6 14 8 16 21 20 4...

Page 44: ...T3 4 T4 5 T5 6 T6 13 14 15 16 17 18 19 20 104 RA 104 RB 115 RCLK A 115 RCLK B 114 TCLK A 114 TCLK B 103 TA 103 TB RCLKWRAP RCLKWRAP TCLKWRAP TCLKWRAP RTS DTR DSR R F S S GND ID0 ID1 ID2 14 16 24 25 4...

Page 45: ...115 RCLK A 115 RCLK B 114 TCLK A 114 TCLK B 103 TA 103 TB TCLKWRAP TCLKWRAP 105 RTS 108 DTR 107 DSR CBL ID0 109 RLS0 CBL ID1 106 RFS CBL ID2 102 GND 22 9 25 24 5 4 14 16 3 13 18 2 20 6 1 8 17 21 7 an...

Page 46: ...ctor Position 1 T1 2 T2 3 T3 4 T4 5 T5 6 T6 7 8 9 10 RA R RB R IA I IB I SA S SB S TA T TB T CA C CB C XA XB GND ID0 ID1 ID2 14 2 18 5 25 12 16 4 17 1 22 10 7 and 15 6 8 21 2 5 13 14 1 Figure 3 36 ARC...

Page 47: ...TA T TB T RA R RB R IA I IB I CA C CB C SA S SB S XA XB GND ID0 ID1 ID2 14 2 16 4 17 1 18 5 22 10 25 12 7 and 15 6 8 21 2 5 13 14 1 Figure 3 38 ARC Cable 3745 X 21 DCE ARC4C 14 1 13 25 1 2 3 4 5 6 7 8...

Page 48: ...DCE ARC3A0 1 2 4 6506 V 35 see Note 1 DCE 2 4 8 6504 V 35 see Note 1 DCE 5 17 6505 V 35 see Note 1 DCE 15 50 6515 V 35 see Note 2 DTE ARC3B0 15 50 6500 V 35 3745 DCE 5 17 6585 Note 1 When connected t...

Page 49: ...DCE 10 33 NLP 58G5624 V 35 DCE 15 50 02L3288 58G5625 V 35 DTE 15 50 02L3289 58G5626 V 35 3745 DCE 6 2 NLP 58G5645 V 35 3745 DCE 1 2 4 NLP 58G5646 V 35 3745 DCE 2 4 8 NLP 58G5647 V 35 3745 DCE 5 17 58G...

Page 50: ...te The ARC V 35 3745 DTE is no longer provided ARC Wrap Plug Pin Assignment 1 2 5 6 14 18 8 4 22 11 12 19 23 24 25 16 26 From To 1 10 19 9 18 26 15 Figure 3 41 ARC V 24 Wrap Plug Pin Assignment PN 58G...

Page 51: ...e The wrap plug PN 58G5658 is no longer provided 1 5 7 8 6 12 2 22 11 17 26 24 25 15 20 From To 1 10 19 9 18 26 Figure 3 44 ARC V 35 DCE 3745 Wrap Plug Pin Assignment PN 58G5659 6 7 8 15 9 18 12 26 24...

Page 52: ...st to Send 5 o o 5 Ready for Sending 19 o o 6 Data Set Ready o o 2 Data Terminal Ready 6 o o 3 Received Data 12 o o 2 Transmitted Data 8 o o 15 Transmitter Signal Element Timing 7 o o 17 Receiver Sign...

Page 53: ...Terminal Ready 6 o o 2 Transmitted Data 8 o o 11 New Synchro o o 14 11 o o 6 Data Set Ready 12 o o 3 Received Data 14 o o 18 Local Loopback 1 o o 15 o o 16 o o 7 Signal Ground 26 o o 18 o o 23 Data S...

Page 54: ...a B 7 o 8 o KK Transmit Clock Wrap B 24 o 8 o HH Transmit Clock Wrap A 8 o 8 o Y Transmit Timing A 26 o 8 o AA Transmit Timing B 9 o 8 o X Receive Timing B 18 o 8 o V Receive Timing A 12 o 8 o P Trans...

Page 55: ...mitted Data A 15 o 8 o S Transmitted Data B 7 o 8 o AA Transmit Timing B 24 o 8 o Y Transmit Timing A 8 o 8 o HH Transmit Clock Wrap A 26 o 8 o KK Transmit Clock Wrap B 11 o o E Data Set Ready 12 o 8...

Page 56: ...ceive A 15 o 8 o 11 Receive B 7 o 8 o 14 Txmit Clk B Txmit Clk Wrap B 24 o 8 o 7 Txmit Clk A Txmit Clk Wrap A 8 o 8 o 6 Signal Timing A 26 o 8 o 13 Signal Timing B 9 o 8 o 12 Indication B 18 o 8 o 5 I...

Page 57: ...B 24 o 8 o 6 Signal Timing A 8 o 8 o 7 Txmit Clk A Txmit Clk Wrap A 26 o 8 o 14 Txmit Clk B Txmit Clk Wrap B 9 o 8 o 1 Control B 18 o 8 o 3 Control A 12 o 8 o 4 Receive A 2 o 8 o 11 Receive B 1 o o 1...

Page 58: ...1 Connector Connector P1 P2 6 o 8 o 2 Transmit A 15 o 8 o 9 Transmit B 7 o 8 o 13 Signal Timing B 24 o 8 o 6 Signal Timing A 8 o 8 o 7 Transmit Clock Wrap A 26 o 8 o 14 Transmit Clock Wrap B 9 o o 17...

Page 59: ...y for Sending 3 o o 6 Cable Id 3745 5 o o 2 Data Terminal Ready 6 o o 14 Transmit Data 8 o o 9 New Synchro 12 o o 16 Receive Data 13 o o 8 Cable Id 1 3745 16 o o 7 Signal Ground 7 o o 15 Signal Ground...

Page 60: ...o 2 Data Terminal Ready 6 o o 14 Transmit Data 8 o o 9 New Synchro Rcv Clk 11 o o 2 Data Set ready 12 o o 16 Receive Data 13 o o 8 Cable Id 1 3745 14 o o 1 Local Loopback 1 o o 15 o o 15 Signal Ground...

Page 61: ...E 24 o 8 o 3 Transmit Clock Wrap A DCE 8 o 8 o 4 Transmit Clock A 26 o 8 o 5 Transmit Clock B 9 o 8 o 25 Receive Clock B 18 o 8 o 24 Receive Clock A 12 o 8 o 22 Transmitted Data A 2 o 8 o 9 Transmitte...

Page 62: ...o 14 Transmitted Data A 15 o 8 o 16 Transmitted Data B 7 o 8 o 4 Transmit Clock B 24 o 8 o 5 Transmit Clock A 8 o 8 o 3 Transmit Clock Wrap A 26 o 8 o 13 Transmit Clock Wrap B 11 o o 2 Data Set Ready...

Page 63: ...nector P1 P2 3 o o 6 Cable ID 3745 6 o 8 o 14 RA R 15 o 8 o 2 RB R 7 o 8 o 1 XB 24 o 8 o 22 XA 8 o 8 o 25 SA S 26 o 8 o 12 SB S 9 o 8 o 5 IB I 18 o 8 o 18 IA I 12 o 8 o 16 TA T 2 o 8 o 4 TB T 13 o o 8...

Page 64: ...P1 P2 3 o o 6 Cable ID 3745 6 o 8 o 14 TA T 15 o 8 o 2 TB T 7 o 8 o 1 SB S 24 o 8 o 22 SA S 8 o 8 o 25 XA 26 o 8 o 12 XB 9 o 8 o 5 CB C 18 o 8 o 18 CA C 1 o o 7 Ground 16 o o 15 Ground 22 o o 12 o 8...

Page 65: ...9352 for the V 35 DCE Wire Number Wire Color Connector 1 Position Connector 2 Position T1 1 T2 2 T3 3 T4 4 T5 5 T6 6 T7 7 T8 8 none black none brown none red none orange none blue none violet none gre...

Page 66: ...for V 35 DTE Wire Number Wire Color Connector 1 Position Connector 2 Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 black white red green orange blue white black red black green black orange black blue...

Page 67: ...nector Female P1 P2 Interchange Circuits 2 3 4 5 6 7 8 2 3 4 5 6 7 8 15 17 20 15 17 20 V 24 Connector V 24 Connector Transmitted Data Receive Data Request to Send Clear to Send Data Set Ready Signal G...

Page 68: ...Subcable A D C B MM m NN n A D C B MM m NN n P1 P2 Connector Male Connector Female Interchange Circuits R T R T V 35 Connector V 35 Connector Xmit Data A Xmit Data B RSET DCE A RSET DCE B TSET DCE A T...

Page 69: ...of the wrap plug is 58X9349 for V 35 The part number of the wrap plug is 58X9354 for X 21 Figure 3 74 LIC12 Wrap Plug Part Number 58X9349 and Part Number 58X9354 See HPTSS Wrap Plugs on page 3 58 for...

Page 70: ...9347 V 35 DTE 5837 10 33 up to 10 33 up to 100 328 76F8635 1 V 35 DTE 7011 10 33 up to 10 33 up to 100 328 58X9348 X 21 DTE 5839 10 33 up to 10 33 76F8636 1 X 21 DTE 7013 10 33 up to 10 33 58X9346 X 2...

Page 71: ...i ns V 3 5 34 Pi ns V 21 15 Pins 50 Pi ns LIC12 To DCE DTE Cable For cable ordering see the HPTSS cable descriptions in the following pages Feature Code The HPTSS cable feature code is 5212 for the 37...

Page 72: ...ble on the manufacturer s DCE Verify that this support exists by reading the documentation on your DCE and select the options that correspond to your cable length 1 2 Interchange Circuits Tail Gate 1...

Page 73: ...8 Request to send 34 o o C 1 5 Clear to send 2 o 5 o D 1 6 V 2 o o B 1 2 Transmit clock2 A 8 o 8 5 o V 115 Transmit clock2 B 7 o 8 5 o X 115 Transmit data A 24 o 8 5 o R 1 4 Transmit data B 25 o 8 5 o...

Page 74: ...ail Gate 1 CCITT X 21 2 V 2 o o 8 G Modem clock B 42 o 8 o 13 S Modem clock A 43 o 8 o 6 S Transmit data A 28 o 8 5 o 2 T Transmit data B 29 o 8 5 o 9 T Receive data A 44 o 8 o 4 R Receive data B 45 o...

Page 75: ...1 NCTE Interface 2 V 2 o o 8 G Modem clock B 42 o 8 o 13 S Modem clock A 43 o 8 o 6 S Transmit data A 28 o 8 5 o 2 T Transmit data B 29 o 8 5 o 9 T Receive data A 44 o 8 o 4 R Receive data B 45 o 8 o...

Page 76: ...m clock A Clock 2 B 12 o 5 o 13 S Modem clock B Clock 1 B 42 o Clock 1 A 43 o Transmit data A 28 o 8 5 o 4 R Receive data A Transmit data B 29 o 8 5 o 11 R Receive data B Receive data A 44 o 8 o 2 T T...

Page 77: ...o 8 o 9 S Modem clock A 43 o 8 o 17 S Local clock B 12 o 8 5 o 11 B Local clock A 11 o 8 5 o 24 B Transmit data A 28 o 8 5 o 2 T Transmit data B 29 o 8 5 o 14 T Receive data A 44 o 8 o 3 R Receive dat...

Page 78: ...4 S Modem clock A Local clock B 42 o o 11 S Modem clock B Clock 2 B 12 o 5 o 9 B Local clock B Clock 2 A 11 o 5 o 17 B Local clock A Transmit data A 28 o 8 5 o 3 R Receive data A Transmit data B 29 o...

Page 79: ...3 V OFF 3 V DTR 1 8 2 ON 3 V OFF 3 V TC 14 ON 3 V OFF 3 V Transmit Data 1 3 a b 275 V 1 a b 275 V Transmit Clock2 113 a b 275 V 1 a b 275 V Receive Local a b 275 V Attach 1 a b 275 V X 21 Interface Tr...

Page 80: ...A 8 o Transmit clock2 B 7 o Transmit data A 24 o Transmit data B 25 o Receive data A 4 o Receive data B 41 o Receive clock A 9 o Receive clock B 1 o ID bit 2 15 o Receive l att clock A 27 o Receive l...

Page 81: ...mber 1 Characteristics E1 120 Ohms Speed 2 048 Mbps LIC16 Wrap Plug The part number of the wrap plug is 57G8097 11 13 15 17 From To 1 10 9 18 26 19 Figure 3 75 LIC16 Wrap Plug Pin Assignment Chapter 3...

Page 82: ...e Connector Male 1 10 20 9 18 26 P1 P2 Figure 3 76 LIC16 E1 Cable Figure 3 77 LIC16 E1 Cable Pin Assignment LIC16 E1 Cable List Table 3 29 LIC16 Cables Cable Type Length m ft Cable PN E1 30 100 80G398...

Page 83: ...complies with the following EU directives EMC 89 336 EEC LVD 73 23 EEC Telecommunications 91 263 EEC Should the PTT require termination of an ISO IEC 10173 plug to connect the LIC16 adapter card then...

Page 84: ...LIC16 3 62 3746 9X0 ECR...

Page 85: ...the Licensed Internal Code LIC for this EC SA33 0172 IBM 3745 Communication Controller Models 210 to 61A IBM 3746 Expansion Unit Model 900 Customer Master Index Provides references for finding inform...

Page 86: ...de GA33 0457 GA33 0127 IBM 3745 Communication Controller Models 210 310 410 and 610 Preparing for Connection Helps for preparing the 3745 Models 210 to 610 cable installation For 3745 Models A refer t...

Page 87: ...sic Operations Guide Provides instructions for daily routine operations on the 3745 Models 130 to 610 SA33 0177 IBM 3745 Communication Controller Models A IBM 3746 Nways Multiprotocol Controller Model...

Page 88: ...Problem Analysis Guide An online guide to analyze alarms events and control panel codes on IBM 3745 Communication Controller Models A IBM 3746 Nways Multiprotocol Controller Models 900 and 950 SA33 0...

Page 89: ...information in the customer documentation library Evaluating and Configuring GA33 0138 IBM 3745 Communication Controller Models 130 150 and 170 Introduction Gives an introduction about the IBM Models...

Page 90: ...ication Controller All Models IBM 3746 Expansion Unit Model 900 IBM 3746 Nways Multiprotocol Controller Model 950 Safety Information Provides general safety guidelines Evaluating and Configuring GA33...

Page 91: ...de and IP Router configuration parameters through its on line help SH11 3081 IBM 3746 Nways Multiprotocol Controller Models 900 and 950 Controller Configuration and Management User s Guide Explains ho...

Page 92: ...references for finding information in the IBM 3745 Models X10 and X1A shipping group documentation SY33 2057 IBM 3745 Communication Controller Models 210 to 61A Installation Guide Provides instruction...

Page 93: ...Model 900 IBM 3746 Nways Multiprotocol Controller Model 950 Service Processor Installation and Maintenance Based on the 7585 3172 or 9585 Provides information on installing and maintaining the servic...

Page 94: ...and line cables used for connecting the IBM 3746 Models 900 and 950 S135 2015 IBM 3746 Nways Multiprotocol Controller Models 900 and 950 Parts Catalog Provides reference information for ordering parts...

Page 95: ...ing via CD ROM viewer EMEA version ZK2T 8187 IBM Networking Softcopy Collection Kit Allows service manuals consulting via CD ROM viewer US version Documentation shipped with the 3745 Documentation shi...

Page 96: ...the IBM 3745 Models 1X0 and 17A SY33 2069 IBM 3745 Communication Controller Models 130 150 160 and 170 Service Functions Describes MOSS functions using the IBM 3745 Models 1x0 and 17A consoles SY33 2...

Page 97: ...ce Based on the 7585 3172 9585 or 9577 Provides information on installing and maintaining the service processor based on PS 2 Types 7585 3172 9585 or 9577 Can be for systems with micro code that has u...

Page 98: ...tocol Controller Models 900 and 950 Parts Catalog Provides reference information for ordering parts for the IBM 3746 Models 900 and 950 S135 2014 IBM Controller Expansion Parts Catalog Provides refere...

Page 99: ...peed HPTSS high performance transmission sub system HSS high speed scanner LIC line interface coupler card LSS low speed scanner MAU media access unit MOSS maintenance and operator subsystem NCTE netw...

Page 100: ...X 2 3746 9X0 ECR...

Page 101: ...he ECBB to the Ethernet bridge 2 1 LCBB to LCBE cable 3 9 LIC11 cable list 3 8 LIC11 to line connection box base cables 3 7 LIC12 attachment cable 3 47 LIC12 cable list 3 48 LIC16 3 60 LIC16 cable lis...

Page 102: ...attach cable HSS 3 51 voltage interface measurements HSS 3 57 W WRAP LIC11 3 6 LIC12 3 47 LIC16 3 59 wrap tools HSS 3 58 X X 21 cable to DCE HSS 3 52 cable to DCE Transfix France HSS 3 53 direct atta...

Page 103: ...nts concerning this book We will greatly appreciate them and will consider them for later releases of the present book If you prefer sending comments by FAX or electronically use FAX 33 4 93 24 77 97...

Page 104: ...We d Like to Hear from You SY33 2117 01 IBM Fold and Tape Please do not staple Fold and Tape PLACE POSTAGE STAMP HERE IBM France Centre d Etudes et Recherches Service 0798 BP 79 06610 La Gaude France...

Page 105: ......

Page 106: ...IBM Part Number 80G5159 Printed in Denmark by IBM Danmark A S 8 G5159 SY33 2117 1...