Message
Explanation
Action
Your server has
an error due to a
Blocked Logical
Drive.
One or more logical drives are
blocked. A blocked logical drive
cannot be accessed. See “Logical
drive-state descriptions” on page 19
for additional information.
Press F4 to unblock the logical drive, or press F5 to continue
without unblocking.
ServeRAID startup (POST) messages
During power-on self-test (POST), the ServeRAID controller compares the stored
configuration information to the configuration that is actually present. If a
discrepancy exists, one or more status messages appear after POST completes,
but before the operating system loads.
When you press F2 for detailed information, register information displays on the
screen, as follows:
ISPR displays the four-digit Interrupt Status Port Register code, BCS displays the
Basic Configuration Status Register code, and ECS displays the Extended
Configuration Status Register code.
If no errors occur:
ISPR = EF10 BCS = 0F or 09 ECS = 00
If an error occurs, refer to: “ISPR (Interrupt Status Port Register) codes” on page 63
for the ISPR error codes and “Basic and Extended Configuration Status Register
Codes” on page 63 for the BCS and ECS error codes.
IBM ServeRAID BIOS
Copyright IBM Corp. 1995, 2000
BIOS Version: 4.10.05
Controller 1 Slot 4, Logical Drive=1, Firmware=4.00.20, Status= Fail
2 Drive(s) not responding or found at new location(s)
Press: F2 - Detailed information
F4 - Retry
F5 - Change the configuration and set drive(s) defunct
F10 - Continue booting without changing the configuration
Detailed information
-------------------------------------------------------------------------
Online Drive on Channel 2 SCSI ID 0 is not responding
Online Drive on Channel 2 SCSI ID 1 is not responding
-------------------------------------------------------------------------
Controller Status Codes: ISPR = EF10 BCS = 07 ECS = 08
Press PgUp = Page Up
PgDn = Page Down
Esc = Exit panel
62
IBM
®
Netfinity
®
: ServeRAID
™
-4L Ultra160 SCSI Controller User’s Reference
Summary of Contents for Netfinity ServeRAID-4L Ultra160
Page 1: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 2: ......
Page 3: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 12: ...x IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 15: ...Part 1 Installation and configuration Copyright IBM Corp 2000 1...
Page 16: ...2 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 34: ...20 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 50: ...36 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 51: ...Part 2 Utility programs Copyright IBM Corp 2000 37...
Page 52: ...38 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 56: ...42 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 64: ...50 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 68: ...54 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 69: ...Part 3 Maintenance and troubleshooting Copyright IBM Corp 2000 55...
Page 70: ...56 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 93: ...Part 4 Appendixes Copyright IBM Corp 2000 79...
Page 94: ...80 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 113: ......