10.
None
of
the
resources
that
are
associated
with
the
B600
5311
SRCs
are
disk
units
that
were
added
to
the
partition
since
the
last
IPL
of
the
partition.
Has
a
scratch
install
recently
been
performed
on
the
partition
that
is
reporting
the
error(s)?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
13
(See
page
11.
If
a
scratch
install
was
not
performed,
was
the
clear
configuration
data
option
recently
used
to
discontinue
LPAR
use?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
Clear
configuration
data
option
was
not
used.
Contact
your
next
level
of
support.
This
ends
the
procedure.
12.
Perform
the
following
to
clear
non-configured
disk
unit
configuration
data:
a.
Go
to
SST/DST
in
the
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Clear
non-configured
disk
unit
configuration
data
.
b.
Select
each
unit
in
the
list
which
is
new
to
the
system
and
press
Enter
.
c.
Continue
the
system
IPL.
This
ends
the
procedure.
13.
Was
the
load
source
device
previously
mirrored
before
the
scratch
install?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
15
(See
page
14.
Perform
the
following
to
clear
the
old
configuration
data
from
the
disk
unit
that
was
mirroring
the
old
load
source
disk
a.
Go
to
SST/DST
in
the
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Clear
non-configured
disk
unit
configuration
data
.
b.
Select
the
former
load
source
mirror
in
the
list
and
press
Enter
.
15.
Is
the
Primary
partition
reporting
the
B600
5311
error(s)?
v
No
:
This
ends
the
procedure.
v
Yes
:
Does
the
customer
want
multiple
partitions
on
the
system?
–
No
:
This
ends
the
procedure.
–
Yes
:
Use
the
Recover
primary
partition
configuration
data
option
to
retrieve
the
LPAR
configuration
data
from
other
devices
in
the
system.
a.
Go
to
SST/DST
in
the
primary
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Recover
primary
partition
configuration
data
.
The
system
will
perform
an
automatic
IPL.
b.
Verify
the
information
that
appears.
-
The
device
should
be
a
former
load
source
device
from
a
secondary
partition.
-
The
time
and
date
should
reflect
a
time
when
that
partition
was
active.
It
should
be
more
recent
than
the
last
change
to
the
logical
partition
configuration.
This
ends
the
procedure.
Operations
Console
PIPs
For
use
by
authorized
service
providers.
For
direct
cable
only.
This
topic
contains
the
procedures
necessary
to
isolate
a
failure
with
the
iSeries
Operations
Console.
The
following
symptoms
can
be
caused
by
iSeries
Operations
Console
failing
to
connect:
v
One
of
the
following
SRCs:
–
A6xx
5001
or
B6xx
5001
146
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation