b.
Copy
the
main
storage
dump
to
removable
media
(see
in
the
iSeries
(TM)
Service
Functions
information).
c.
Provide
your
next
level
of
support
with
this
information.
This
ends
the
procedure.
v
Yes
:
Use
the
SRC
information
from
the
original
failure
and
return
to
Analyze
the
problem
using
the
data
in
characters
9-16
of
the
bottom
16
character
line
of
function
13
(word
9)
on
the
Problem
Summary
Form
in
place
of
word
1.
This
ends
the
procedure.
Logical
partition
(LPAR)
PIP
For
use
by
authorized
service
providers.
Use
this
page
to
identify
logical
partition
(LPAR)
configuration
conditions
and
the
associated
corrective
actions.
LPAR-PIP01:
Use
this
procedure
to
identify
Logical
Partition
(LPAR)
configuration
conditions
and
their
associated
corrective
actions.
1.
Is
there
only
one
B6005311
error
logged,
and
is
it
against
the
load
source
device
for
the
partition,
in
either
the
Primary
or
a
secondary
partition?
v
Yes
:
Is
the
reporting
partition
the
Primary
partition?
–
Yes
:
Continue
with
the
next
step.
–
No
:
Go
to
step
3
(See
page
v
No
:
Go
to
step
4
(See
page
2.
Was
the
load
source
disk
unit
migrated
from
another
partition
within
the
same
system?
v
Yes
:
Is
this
load
source
device
intended
to
be
the
load
source
for
the
Primary
partition?
–
Yes
:
To
accept
the
load
source
disk
unit:
Go
to
SST/DST
in
the
current
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Accept
load
source
disk
unit
.
This
ends
the
procedure.
–
No
:
Power
off
the
system.
Return
the
original
load
source
disk
to
the
Primary
partition
and
perform
a
system
IPL.
This
ends
the
procedure.
v
No
:
The
load
source
disk
unit
has
not
changed.
Contact
your
next
level
of
support.
This
ends
the
procedure.
3.
The
reporting
partition
is
a
secondary
partition.
Since
the
last
IPL
of
the
reporting
partition,
have
one
of
the
following
occurred?
v
Has
the
Primary
partition
time/date
been
moved
backward
to
a
time/date
earlier
than
the
previous
setting?
v
Has
the
system
serial
number
been
changed?
v
Was
the
load
source
disk
unit
in
this
secondary
partition,
replaced
intentionally
with
a
load
source
from
another
system
or
another
partition
from
the
same
system?
v
Yes
:
To
accept
the
load
source
disk
unit:
Go
to
SST/DST
in
the
current
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Accept
load
source
disk
unit
This
ends
the
procedure.
v
No
:
Contact
your
next
level
of
support.
This
ends
the
procedure.
4.
Are
there
multiple
B600
5311
SRCs
logged
in
the
same
partition?
v
Yes
:
Continue
with
the
next
step.
v
No
:
None
of
the
conditions
in
this
procedure
have
been
met,
call
your
next
level
of
support.
This
ends
the
procedure.
144
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and