For details on the Failing Item column entries, see the SPCN Failing Items Detail
table, which follow the Reference Code tables below.
For system Models 870 and 890, SPCN Reference Codes
:
Choose from the following code format and table identifier:
Note:
On Models 870 and 890, the A, B, or C in the SRC (1xxA xxxx, 1xxB xxxx, or
1xxC xxxx) indicates that the failure is on the processor frame, not on the FC
9094 Base I/O Tower.
v
Table 1. SPCN reference codes for system Models 870 and 890 with table
identifier 90
v
Table 2. SPCN reference codes for system Models 870 and 890 with table
identifier A0
v
Table 3. SPCN reference codes for system Models 870 and 890 with table
identifier B0
Table 1. SPCN reference codes for system Models 870 and 890 with table
identifier 90
:
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
00A0
SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
00AA
Download in process
No action required. This reference code is logged for information only.
00AC
Detected AC loss
If system powers on normally or stays powered on after AC power failure,
no replacement of parts may be needed.
00BA
The system is running on the Battery Power Unit.
No action required. This reference code is displayed for information only.
00BC
Battery Power Unit test is in process.
No action required. This reference code is displayed for information only.
00CA
Thermal calibration in progress
00EF
Remote EPO switch is OFF
1500
Detected AC loss
Before replacing any parts, verify that the AC input voltage is correct.
1501
Power supply failure
1502
Power supply failure
1503
Power supply failure
1510
Detected AC loss
Before replacing any parts, verify that the AC input voltage is correct.
1xxx
System Reference Codes