Cleaning the Drive Head
Attention:
When cleaning the drive head, use the IBM LTO Ultrium Cleaning
Cartridge (see “Media Supplies” on page C-5). You may use another LTO cleaning
cartridge, but it may not meet the standards of reliability established by IBM.
Clean the drive head whenever
C
displays on the Single-character Display and
the Fault light is flashing once per second. It is not recommended that you clean
the drive head on a periodic basis; only when the drive requests to be cleaned.
Note:
In Maintenance Mode, a flashing
C
with the Fault light On, means to
insert a cartridge, not clean the drive head.
To clean the head, insert the cleaning cartridge into the tape load compartment (see
“Front panel of the drive” on page 1-2). The drive performs the cleaning
automatically in less than two minutes then ejects the cartridge. The drive will
perform a short Load/Unload Test while ejecting the drive. Wait for the drive to
finish before removing the cartridge.
Note:
The drive will automatically eject an expired cleaning cartridge.
The IBM LTO Ultrium Cleaning Cartridge is valid for 50 uses.
Cleaning the tape drive
Clean the exterior surface of the tape drive with a damp towel. If a liquid
all-purpose cleaner is used, apply it to the towel. Do not spray the tape drive.
Diagnostic and Maintenance Functions
The drive can:
v
Run diagnostics
v
Test write and read functions
v
Test a suspect tape cartridge
v
Update firmware
v
Perform other diagnostic and maintenance functions
The drive must be in maintenance mode to perform these functions.
Attention:
Maintenance functions cannot be performed concurrently with read or
write operations. While in maintenance mode, the tape drive does not accept host
interface commands from the server.
Table 3-3 on page 3-8 describes each diagnostic and maintenance function that the
drive can perform, gives the function code which appears on the Single-character
Display (SCD), and directs you to the instructions for performing the function. It is
recommended that you use a customer-supplied scratch (blank) data cartridge for
diagnostic testing.
Note:
During normal operation the fan only runs when cooling is required. The
fan will be turned on/off during the POST and Run Drive Diagnostics to
demonstrate the fan is operational.
Chapter 3. Operating
3-7
Summary of Contents for H5S
Page 2: ......
Page 6: ...iv TS2250 Tape Drive Setup Operator and Service manual...
Page 8: ...vi TS2250 Tape Drive Setup Operator and Service manual...
Page 12: ...x TS2250 Tape Drive Setup Operator and Service manual...
Page 14: ...xii TS2250 Tape Drive Setup Operator and Service manual...
Page 22: ...xx TS2250 Tape Drive Setup Operator and Service manual...
Page 24: ...xxii TS2250 Tape Drive Setup Operator and Service manual...
Page 34: ...1 8 TS2250 Tape Drive Setup Operator and Service manual...
Page 44: ...2 10 TS2250 Tape Drive Setup Operator and Service manual...
Page 90: ...B 2 TS2250 Tape Drive Setup Operator and Service manual...
Page 98: ...C 8 TS2250 Tape Drive Setup Operator and Service manual...
Page 106: ...D 8 TS2250 Tape Drive Setup Operator and Service manual...
Page 128: ...F 8 TS2250 Tape Drive Setup Operator and Service manual...
Page 147: ......
Page 148: ...Part Number 46C2120 Printed in USA GC27 2275 02 1P P N 46C2120...