background image

IBM Flex System x240 Compute Node

12

At least one hardware kit is required with the ServeRAID M5115 controller, and there are three hardware 
kits that are supported that enable specific drive support:

ServeRAID M5100 Series Enablement Kit for IBM Flex System x240 

(90Y4342) enables support 

for up to two 2.5” HDDs or SSDs in the hot-swap bays in the front of the server. It includes a 
CacheVault unit, which enables MegaRAID CacheVault flash cache protection. This enablement kit 
replaces the standard two-bay backplane (which is attached via the planar to an onboard controller) 
with a new backplane that attaches to an included flex cable to the M5115 controller. It also includes 
an air baffle, which also serves as an attachment for the CacheVault unit.

MegaRAID CacheVault flash cache protection uses NAND flash memory powered by a 
supercapacitor to protect data stored in the controller cache. This module eliminates the need for a 
lithium-ion battery commonly used to protect DRAM cache memory on PCI RAID controllers. To avoid 
the possibility of data loss or corruption during a power or server failure, CacheVault technology 
transfers the contents of the DRAM cache to NAND flash using power from the supercapacitor. After 
the power is restored to the RAID controller, the saved data is transferred from the NAND flash back 
to the DRAM cache, which can then be flushed to disk.

Tip

: The Enablement Kit is only required if 2.5-inch drives are to be used. If you plan to install four or 

eight 1.8-inch SSDs only, then this kit is not required.

ServeRAID M5100 Series IBM eXFlash Kit for IBM Flex System x240 

(90Y4341) enables eXFlash 

support for up to four 1.8-inch SSDs. This kit replaces the standard two-bay backplane with a four-bay 
eXFlash backplane that attaches to an included flex cable to the M5115 controller. Because only 
SSDs are supported, a CacheVault unit is not required, and therefore this kit does not have a 
supercap.

ServeRAID M5100 Series SSD Expansion Kit for IBM Flex System x240 

(90Y4391) enables 

support for up to four internal 1.8-inch SSDs. This kit includes two air baffles, left and right, which can 
attach two 1.8-inch SSD attachment locations and Flex cables for attachment to up to four 1.8-inch 
SSDs. 

The following table shows the kits required for each combination of drives. For example, if you plan to 
install eight 1.8-inch SSDs, then you will need the M5115 controller, the eXFlash kit, and the SSD 
Expansion kit.

Table 7. ServeRAID M5115 hardware kits

Desired drive support

Components required

Maximum
number of
2.5" drives

Maximum
number of
1.8" SSDs

ServeRAID
M5115 
90Y4390

Enablement Kit 
90Y4342

eXFlash Kit 
90Y4341

SSD
Expansion Kit 
90Y4391

2

0

=>

Add this

... and this

0

4 (front)

=>

Add this

... and this

2

4 (internal)

=>

Add this

... and this

... and this

0

8 (both)

=>

Add this

... and this

... and this

Summary of Contents for Flex System x240 Compute Node

Page 1: ...web HPC Microsoft RemoteFX and cloud applications Figure 1 shows the IBM Flex System x240 Compute Node Figure 1 The IBM Flex System x240 Compute Node Did you know IBM Flex System is a new category of...

Page 2: ...kloads Intel Advanced Vector Extensions AVT significantly improve floating point performance for compute intensive technical and scientific applications compared with Intel Xeon 5600 series processors...

Page 3: ...e x240 The x240 includes an Integrated Management Module II IMM2 to monitor server availability and perform remote management Integrated industry standard Unified Extensible Firmware Interface UEFI en...

Page 4: ...ments Low voltage 1 35 V DDR3 memory RDIMMs consume 15 less energy than 1 5 V DDR3 RDIMMs Solid state drives SSDs consume as much as 80 less power than traditional spinning 2 5 inch HDDs The x240 uses...

Page 5: ...to 20 MB L3 cache Chipset Intel C600 series Memory Up to 24 DIMM sockets 12 DIMMs per processor using Low Profile LP DDR3 DIMMs RDIMMs UDIMMs and LRDIMMs supported 1 5 V and low voltage 1 35 V DIMMs...

Page 6: ...ment Kit Console breakout cable port providing local KVM and serial ports cable standard with chassis additional cables optional Systems management UEFI IBM Integrated Management Module 2 IMM2 with Re...

Page 7: ...L2x 1x Xeon E5 2660 8C 2 2GHz 20MB 1600MHz 95W 2x 4 GB SAS SATA RAID 2 5 hot swap 0 2 Open Standard 1 2 8737 M1x 1x Xeon E5 2680 8C 2 7GHz 20MB 1600MHz 130W 2x 4 GB SAS SATA RAID 2 5 hot swap 0 2 Open...

Page 8: ...Hz 70W 81Y5186 Intel Xeon Processor E5 2650 8C 2 0GHz 20MB Cache 1600MHz 95W 81Y5179 Intel Xeon Processor E5 2650L 8C 1 8GHz 20MB Cache 1600MHz 70W 95Y4675 Intel Xeon Processor E5 2658 8C 2 1GHz 20MB...

Page 9: ...V 1 35 V 1 35 V Operating voltage 1 35 V 1 5 V 1 35 V 1 5 V 1 5 V 1 35 V 1 5 V 1 5 V 1 35 V 1 5 V 1 35 V 1 5 V Max quantity 16 16 16 24 24 16 24 24 8 16 24 24 Largest DIMM 4 GB 4 GB 4 GB 4 GB 4 GB 16...

Page 10: ...C3 12800 CL11 ECC DDR3 1600MHz LP RDIMM 90Y3109 8GB 1x8GB 2Rx4 1 5V PC3 12800 CL11 ECC DDR3 1600MHz LP RDIMM 49Y1397 8GB 1x8GB 2Rx4 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP RDIMM 49Y1563 16GB 1x16GB 2...

Page 11: ...M 256GB SATA 2 5 MLC HS Entry SSD 2 90Y8648 IBM 128GB SATA 2 5 MLC HS Entry SSD 2 Support for eXFlash 1 8 solid state drives In addition the x240 supports eXFlash with up to eight 1 8 inch solid state...

Page 12: ...rred from the NAND flash back to the DRAM cache which can then be flushed to disk Tip The Enablement Kit is only required if 2 5 inch drives are to be used If you plan to install four or eight 1 8 inc...

Page 13: ...CacheVault flash cache protection row 1 of the preceding table Figure 4 The ServeRAID M5115 and the Enablement Kit installed The following figure shows how the ServeRAID M5115 and eXFlash and SSD Expa...

Page 14: ...me array drive group not recommended Optional support for SSD performance acceleration with MegaRAID FastPath and SSD caching with MegaRAID CacheCade Pro 2 0 90Y4447 Support for up to 64 virtual drive...

Page 15: ...es the SSDs to be configured as a dedicated cache to help maximize the I O performance for transaction intensive applications such as databases and web serving The feature tracks data storage access p...

Page 16: ...be routed to I O module bay 2 The Fabric Connector can be unscrewed and removed if required to allow the installation of an I O adapter on I O connector 1 The Embedded 10Gb VFA is based on the Emulex...

Page 17: ...ation of the I O adapter slots in the IBM Flex System x240 Compute Node All I O adapters are the same shape and can be used in any available slot A compatible switch or pass through module must be ins...

Page 18: ...the IBM Flex System Enterprise Chassis Figure 7 Location of the switch bays in the IBM Flex System Enterprise Chassis The following figure shows how two port adapters are connected to switches install...

Page 19: ...network switches The following table lists the supported network adapters and upgrades Adapters can be installed in either slot However compatible switches must be installed in the corresponding bays...

Page 20: ...f VMware ESXi and is fully contained on the flash drive without requiring any disk space The USB memory key plugs into one of the USB ports on the optional x240 USB Enablement Kit 49Y8119 The kit offe...

Page 21: ...f the LEDs in the light path diagnostics panel are listed in the following table Table 15 Light path diagnostic panel LEDs LED Meaning LP The light path diagnostics panel is operational S BRD A system...

Page 22: ...ette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server Uploading a diskette image to the IMM2 memory and...

Page 23: ...is is the supported operating environment Power on Temperature 5 40 C 41 104 F Humidity non condensing 12 C dew point 10 4 F and 8 85 relative humidity Maximum dew point 24 C 75 F Maximum altitude 304...

Page 24: ...to arrive at your customer s location within four hours after remote problem determination is completed We provide 24 hour service every day including IBM holidays 9x5x4 hour A service technician is s...

Page 25: ...s needs IBM Global Financing has the breadth and depth of offerings longevity proven success and global reach to help you develop a robust financing and asset management strategy that provides you the...

Page 26: ...oduct page http ibm com systems flex compute nodes x86 bto IBM Flex System Information Center Available May 21 http publib boulder ibm com infocenter flexsys information index jsp IBM Flex System x240...

Page 27: ...the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any o...

Page 28: ...ublished Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The follo...

Reviews: