![IBM DS3500 Installation, User & Maintenance Manual Download Page 40](http://html1.mh-extra.com/html/ibm/ds3500/ds3500_installation-user-and-maintenance-manual_3358478040.webp)
CAUTION:
or
>18 kg (39.7 lb)
or
18-32 kg (39.7-70.5 lb)
The weight of this part or unit is between 18 and 32 kg (39.7 and 70.5 lb).
It takes two persons to safely lift this part or unit. (C009)
3. Make sure that you have the correct host software for your operating system.
The support DVD that comes with the DS3500 has the correct DS Storage
Manager host software.
The DVD also includes the storage subsystem controller firmware. For the latest
controller firmware, see http://www.ibm.com/servers/storage/support/disk/.
4. Read the applicable readme files that are included in the DS Storage Manager
host software or DS3500 controller firmware packages for any updated
information about hardware, software, or firmware products.
5. Continue with “Required tools and hardware.”
Required tools and hardware
Have the following tools and equipment available:
v
Region-specific power cords
v
5/16 (8 mm) hex nut driver
v
#0 and #1 Phillips screwdrivers
v
Electrostatic-discharge protection (such as a grounding wrist strap)
v
Rack power jumper cords
v
Rack-mounting hardware
v
Ethernet interface cables and cable straps (depending on configuration)
v
SAS cables (depending on configuration)
v
Fibre Channel cables, interface cables, and cable straps (depending on
configuration)
v
SFP modules (depending on configuration)
Preparing the site
This section lists the floor space requirements and weight information for the
DS3500. For information about interface cables and connections, see Chapter 3,
“Cabling the storage subsystem and expansion enclosure,” on page 23.
The floor area at the installation site must provide the following conditions:
v
Sufficient space to install the DS3500 storage subsystem
v
Enough stability to support the weight of the fully configured DS3500 storage
subsystem and associated devices (see “Weight” on page 13).
Make sure that all requirements, such as floor space, air conditioning, and electrical
service, have been met. Other site preparation activities include the following tasks:
v
Make sure that there is enough room to move around the rack and install the
modules.
v
Install uninterruptible-power-supply devices.
20
System Storage DS3500 and EXP3500: Installation, User’s, and Maintenance Guide
Summary of Contents for DS3500
Page 1: ...System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 2: ......
Page 3: ...System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 12: ...x System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 14: ...xii System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 20: ...xviii System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 86: ...66 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 112: ...92 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 174: ...154 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 179: ......