Field
replacement
for
the
DR550
Storage
Controller
This
section
describes
field
replacement
procedures
for
the
DR550
Storage
Controller
component.
Replacing
a
DR550
Storage
Controller
canister
Attention:
Before
you
replace
a
DR550
controller,
verify
the
following:
v
The
replacement
controller
part
number
matches
the
part
number
of
the
controller
to
be
replaced.
To
provide
full
functionality,
the
two
controllers
should
have
the
same
cache
memory
capacity
and
FRU
part
number.
Inserting
a
non-compatible
controller
causes
the
controller
to
be
placed
in
a
lockout
state
by
the
other
controller
in
the
DR550
Storage
Controller
chassis.
Note:
The
DR550
Storage
Controller
Subsystem
controller
FRU
is
not
compatible
with
the
DS4700
Storage
Subsystem
controller
FRUs.
v
Both
power
supply
and
fan
units
must
be
connected
and
powered
on
with
no
Needs
Attention
LEDs
lit.
Ensure
that
the
Power
LEDs
on
each
of
the
power
supply
and
fan
units
are
lit.
If
either
of
the
power
supply
and
fan
units
is
not
optimal,
it
is
recommended
that
you
replace
that
component
before
you
proceed
with
the
controller
replacement
procedure.
v
If
you
are
replacing
an
optimal
controller,
first
make
sure
that
the
other
controller
is
optimal
and
that
the
fibre
channel
path
from
the
hosts
to
the
other
controller
is
also
optimal.
Use
the
following
procedure
to
replace
a
controller
in
a
DR550
Storage
Controller
Storage
Subsystem.
Each
controller
has
a
unique
hardware
Ethernet
address,
which
is
printed
on
a
label
on
the
front.
1.
Use
the
DS4000
Storage
Manager
client
software
to
a
storage
subsystem
profile.
Move
logical
drive
ownership
to
the
other
controller.
If
the
controller
you
are
replacing
has
failed
but
is
still
operating,
move
the
failed
controller
to
an
Offline
state.
Attention:
Never
remove
a
controller
unless
the
Service
Action
Allowed
status
LED
is
turned
on.
Doing
so
can
result
in
a
potential
loss
of
data.
2.
Locate
the
failed
controller
by
checking
the
Needs
Attention
status
LEDs
on
the
controllers
in
the
storage
subsystem.
3.
Is
the
Service
Action
Allowed
status
LED
turned
on?
v
Yes
–
Go
to
step
v
No
–
Another
component
might
require
attention
before
you
can
remove
the
controller.
Use
the
Recovery
Guru
function
in
the
DS4000
Storage
Manager
for
DR550
Subsystem
Management
window
to
identify
and
correct
any
additional
failures.
If
there
are
none,
proceed
with
step
to
replace
the
controller.
Electrostatic
discharge
can
damage
sensitive
components.
Touching
the
storage
subsystem
or
its
components
without
using
a
proper
ground
might
damage
the
equipment.
To
avoid
damage,
use
proper
antistatic
protection
while
handling
any
components.
4.
Put
on
antistatic
protection.
5.
Unpack
the
new
controller.
Save
all
packing
materials
in
the
event
you
need
to
return
the
new
controller.
110
DR550
Version
4.5
Problem
Determination
and
Service
Guide
Summary of Contents for DR550
Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 2: ......
Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Printed in USA GA32 0576 00...