a.
Open the two release levers as shown in the illustration. The power supply
moves out of the bay approximately 0.6 cm (0.25 inch).
b.
Slide the power supply out of the bay and set it aside.
8.
Place the replacement power supply on a level surface.
9.
Ensure that the release levers on the power supply are in the open position.
10.
Slide the power supply into the bay until it stops.
11.
Push the release levers to the closed position.
12.
Connect the power cord and turn on the power.
13.
Check the power and fault LEDs on the new unit.
14.
Check the status of the power and fault LEDs. The procedure to follow
according to the LED status is as under:
v
The fault LED is lit and the ac and dc power LEDs are off:
The new unit
might be installed incorrectly. The power-supply switch might not be
turned on. The power cord connector might not be fully inserted into the
power receptacle or the power-supply ac socket. There might not be any
power to the receptacle that the power supply is connected to. The power
cord might be faulty. Go to step 15.
v
The fault and ac power LEDs are lit but the dc power LED is off:
The
power supply is faulty. Turn off the power switch and contact your IBM
technical-support representative for a replacement power supply.
v
The ac and dc power LEDs are lit but the fault LED is off:
Go to step 16
15.
Perform the following substeps to solve the problem:
v
Ensure that the power switch is turned on.
v
Ensure that there is power at the ac outlet and no circuit breaker has
tripped.
v
Ensure that the power cord is working and fully seated into the electrical
receptacle and the power supply ac connector.
v
Reinstall the power supply.
If these tasks do not solve the problem, contact your IBM technical-support
representative.
AC
DC
2
1
I
O
dcsi0024
Figure 49. Replacing a power supply
102
IBM System Storage DCS3860 Storage System: Installation, User's, and Maintenance Guide
Summary of Contents for DCS3860
Page 6: ...vi IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 8: ...viii IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 42: ...24 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 72: ...54 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 94: ...76 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 140: ...122 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 158: ...140 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 162: ...144 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 166: ...148 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 174: ...156 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 178: ...160 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 202: ...184 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 203: ......
Page 204: ...Part Number 46W6954 Printed in USA SC27 5942 00 1P P N 46W6954...