Procedure
1.
Ensure that you removed both power cords from the system. For instructions, see “Disconnecting the
power cords from an 8001-12C, 8001-22C, 8005-12N, or 8005-22N system” on page 85.
(L005)
>240VA
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when
shorted with metal, which might result in splattered metal, burns, or both. (L005)
2.
Remove the two cover screws (1), from the rear of the cover.
3.
Press both buttons on the top cover (2) to release the latches as shown in Figure 82, and push the
cover back about 0.5 in (1 cm) until it stops. If the buttons do not easily press down, partially remove
the drives directly under the buttons.
4.
Lift up the front of the cover up and remove it from the system.
Installing the service access cover on an 8001-12C or 8005-12N system
Learn how to install the service access cover on a rack-mounted IBM Power System S821LC (8001-12C) or
the IBM CS821 (8005-12N) system.
Figure 82. Releasing and opening the cover