Table
7.
Light
path
diagnostics
LED
Problem
Action
None
An
error
has
occurred
and
cannot
be
isolated,
or
the
service
processor
has
failed.
The
error
is
not
represented
by
a
light
path
diagnostics
LED.
Check
the
system
error
log
in
the
management
module
for
more
information
about
the
error.
DIMM
x
error
A
memory
error
has
occurred.
Replace
the
failing
DIMM,
which
is
indicated
by
the
lit
DIMM
failure
LED.
Note:
Multiple
DIMM
LEDs
do
not
necessarily
indicate
multiple
DIMM
failures.
If
more
than
one
DIMM
LED
is
lit,
reseat
or
replace
one
DIMM
at
a
time
until
the
error
is
corrected.
Check
the
system
error
log
in
the
management
module
for
information
about
the
error.
If
the
problem
remains,
have
the
blade
server
serviced.
SAS
hard
disk
drive-LED
Reserved
Reserved
Processor
x
error
The
microprocessor
has
failed.
Make
sure
that
the
microprocessor
that
is
indicated
by
the
lit
LED
is
installed
correctly
(see
for
installation
instructions).
If
the
problem
remains,
have
the
blade
server
serviced.
Temperature
error
(TEMP)
The
system
temperature
has
exceeded
a
threshold
level.
v
Determine
whether
a
blower
on
the
BladeCenter
unit
has
failed.
If
it
has,
replace
the
blower.
v
Make
sure
that
the
room
temperature
is
not
too
high
(see
for
temperature
information).
If
the
problem
remains,
have
the
blade
server
serviced.
System
board
error
(S
BRD)
The
system
board
has
failed
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
BladeCenter
unit,
and
then
restart
the
server.
If
the
problem
remains,
have
the
blade
server
serviced.
NMI
error
The
system
board
has
failed.
v
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
BladeCenter
unit,
and
then
restart
the
server.
v
Check
the
system
error
log
in
the
management
module
for
information
about
the
error.
If
the
problem
remains,
have
the
blade
server
serviced.
Processor
mismatch
(MIS)
The
processors
do
not
match.
Make
sure
that
microprocessors
1
and
2
have
the
same
cache
size
and
type
and
the
same
clock
speed.
Internal
and
external
clock
frequencies
must
be
identical.
If
the
problem
remains,
have
the
blade
server
serviced.
Chapter
6.
Solving
problems
61
Summary of Contents for BladeCenter HS20
Page 3: ...BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 24: ...12 BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 32: ...20 BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 60: ...48 BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 74: ...62 BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 86: ...74 BladeCenter HS20 Type 7981 Installation and User s Guide...
Page 87: ......
Page 88: ...Part Number 31R1715 Printed in USA 1P P N 31R1715...