background image

IBM BladeCenter 1/10 Gb Uplink Ethernet Switch
Module

Installation Guide

Summary of Contents for BladeCenter 1/10 Gb Uplink Ethernet...

Page 1: ...IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 2: ......

Page 3: ...IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 4: ...ad the Safety document and the License Agreement for Machine Code LAMC document on the IBM Documentation CD Read the IBM Systems Environmental Notices document on the Environmental Notices CD Second E...

Page 5: ...cable 15 Disconnecting the serial console cable 15 Connecting the SFP module cable 15 Disconnecting the SFP module cable 16 Connecting the RJ 45 cable 16 Disconnecting the RJ 45 cable 17 Chapter 5 Up...

Page 6: ...t 37 European Union EMC Directive conformance statement 37 Taiwanese Class A warning statement 37 Germany Electromagnetic Compatibility Directive 38 Deutschland Einhaltung des Gesetzes ber die elektro...

Page 7: ...tteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare que...

Page 8: ...ument For example if a caution statement is labeled Statement 1 translations for that caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger...

Page 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Page 10: ...mbedded Class 3A or Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam Cla...

Page 11: ...s the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you s...

Page 12: ...x IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 13: ...t http www ibm com systems bladecenter Notes 1 Throughout this document the IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module is referred to as the switch module or the I O module 2 Unless otherwi...

Page 14: ..._________ _____________________________________________ Specifications For detailed information about the switch module hardware and software features specifications and standards see the Application...

Page 15: ...for replacement Notices and statements in this document The caution and danger statements in this document are also in the multilingual Systems Safety Notices document which is on the BladeCenter Doc...

Page 16: ...major components of the switch module Note The illustrations in this document might differ slightly from your hardware and your switch module might have labels that are not shown in the illustrations...

Page 17: ...enter unit might vary You can obtain up to date information about the switch module and the BladeCenter unit at http www ibm com systems bladecenter Installation guidelines Before you install the swit...

Page 18: ...l you are ready to install them To reduce the possibility of electrostatic discharge observe the following precautions v Limit your movement Movement can cause static electricity to build up around yo...

Page 19: ...ts static protective package 6 Make sure that the release lever on the switch module is in the open position perpendicular to the module For specific instructions for installing a switch module in the...

Page 20: ...rmation that begins on page v and Installation guidelines on page 5 2 Disconnect any cables from the switch module that you are removing Removing these cables especially an Ethernet cable disrupts the...

Page 21: ...ch module For additional information about cabling the switch module see Chapter 4 Cabling the switch module and the SFP module on page 15 and the documentation that comes with the cables and the opti...

Page 22: ...10 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 23: ...v Use minimal pressure when you insert the module into the port Forcing the module into the port can cause damage to the module or the module port v You can insert or remove the module while the Blade...

Page 24: ...ckage that contains the SFP module to an unpainted metal surface of the BladeCenter chassis or an unpainted metal surface on any other grounded rack component in the rack in which you are installing t...

Page 25: ...ving the cable see Disconnecting the SFP module cable on page 16 Attention To avoid damage to the cable or the SFP module make sure that you disconnect the fiber optic cable before you remove the SFP...

Page 26: ...14 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 27: ...gently pull the cable from the switch module Connecting the SFP module cable Attention To avoid damage to the fiber optic cables follow these guidelines v Do not route the cable along a folding cable...

Page 28: ...release tabs and gently pull the fiber optic cable from the SFP module 2 Replace the protective caps on the ends of the fiber optic cable Connecting the RJ 45 cable RJ 45 cables can be connected to po...

Page 29: ...t the RJ 45 connector squeeze the release tab and gently pull the cable connector out of the switch module connector You might have to use a tool such as a small flat blade screwdriver Chapter 4 Cabli...

Page 30: ...18 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 31: ...r unit type for additional information Make sure that you are using the latest version of the switch module software For instructions on upgrading the switch module software see the Menu Based CLI Com...

Page 32: ...20 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 33: ...the external connections to the switch module For further details about LEDs see Information LEDs on page 22 v Three SFP port connectors to attach SFP modules These connectors are identified as ports...

Page 34: ...remain lit during POST and then all the LEDs except the OK LED turn off Any errors that are detected during POST are written to the system log For information about the command to read the system log...

Page 35: ...nter unit is also lit v When this LED is off and the green LED is lit it indicates that the switch module is working correctly If the green LED is also off it indicates that the switch module is off L...

Page 36: ...24 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 37: ...ly by trained service technicians For information about the terms of the warranty see the warranty that ships with your switch module The replaceable components in the following table are Tier 1 CRUs...

Page 38: ...26 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 39: ...l of the management module The specific failure is displayed on the system status I O module panel of the management module Note For the locations and descriptions of the switch module LEDs see Chapte...

Page 40: ...corresponding failure You might have to provide this information when you call for service For details see Appendix A Getting help and technical assistance on page 29 Diagnostic indicator in hex Faili...

Page 41: ...erproven compat us to make sure that the hardware and software is supported by your IBM product v Go to http www ibm com supportportal to check for information to help you solve the problem v Gather t...

Page 42: ...formation is http www ibm com systems bladecenter The address for IBM IntelliStation information is http www ibm com systems intellistation How to send Dynamic System Analysis data to IBM Use the IBM...

Page 43: ...tp www ibm com partnerworld and click Find Business Partners on the right side of the page For IBM support telephone numbers see http www ibm com planetwide In the U S and Canada call 1 800 IBM SERV 1...

Page 44: ...32 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 45: ...ess or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically m...

Page 46: ...ion by any means whatsoever to interfaces of public telecommunications networks nor to be used in a public services network Further certification may be required by law prior to making any such connec...

Page 47: ...s that maintain particulate and gas levels that are consistent with the protection of human health and safety If IBM determines that the levels of particulates or gases in your environment have caused...

Page 48: ...CC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiat...

Page 49: ...relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product including...

Page 50: ...ng Dieses ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funk St rungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Ma nahmen zu ergreifen und da...

Page 51: ...Japanese Voluntary Control Council for Interference VCCI statement Korean Class A warning statement Appendix B Notices 39...

Page 52: ...40 IBM BladeCenter 1 10 Gb Uplink Ethernet Switch Module Installation Guide...

Page 53: ...bles 16 serial console cable 15 SFP module cable 16 contamination particulate and gaseous 35 critical errors 27 D danger statements 3 diagnostic data 30 disconnecting RJ 45 cables 17 serial console ca...

Page 54: ...module 8 9 serial console cable 15 SFP module 12 SFP module cable 16 installation continued procedure continued switch module 7 requirements 5 installing fiber optic cables 16 high speed switch modul...

Page 55: ...ecting 16 disconnecting 17 S safety certification label 4 serial console cable connecting 15 disconnecting 15 parts listing 25 serial number label 4 location of 2 ServerProven list IBM 6 SFP module ca...

Page 56: ...lectronic emission Class A notice 36 United States FCC Class A notice 36 W Web site BladeCenter documentation 2 6 compatible BladeCenter options 6 IBM product information 1 IBM ServerProven list 1 6 p...

Page 57: ......

Page 58: ...Part Number 00D9264 Printed in USA 1P P N 00D9264...

Reviews: