![background image](http://html1.mh-extra.com/html/ibm/accesser-4105/accesser-4105_appliance-manual_3471052043.webp)
3.
Secure the chassis to the rails with the captive M6 thumbscrews on the server.
Cable the appliance
1.
On the rear panel, connect the C13 end of the power cables to the C14 inlets in the PSU, as shown in
the following figure.
2.
The Ethernet connections are located just to the left of the center of the appliance and are next to each
other. Connect a standard Ethernet cable from the left Ethernet port.
3.
Press the power button on the top far right corner of the appliance front panel when the bezel is
unscrewed and flipped down.
4.
To ensure that the power is on, verify that the power and network link lights are lit and listen for
running fans, as shown in the following figure.
Figure 10. Push chassis into rack
Figure 11. Rear of appliance
Figure 12. Front of appliance
Chapter 4. Install the appliance into a rack
25
Summary of Contents for Accesser 4105
Page 4: ...iv IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 6: ...vi IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 10: ...x IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 16: ...xvi IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 20: ...2 IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 36: ...18 IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 44: ...26 IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 52: ...34 IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 64: ...46 IBM Cloud Object Storage System Accesser 4105 Appliance Manual 3409 A01 3401 A01 3403 A01...
Page 65: ......
Page 66: ...IBM Printed in USA...