Diagnostic Error Code
FRU/Action
170-195-XXX
Voltage Sensor(s) Test aborted by user
1.
Information
2.
Re-start the test, if necessary
170-196-XXX
Voltage Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
170-197-XXX
Voltage Sensor(s) test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
170-198-XXX
Voltage Sensor(s) test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″
Undetermined problems
″
section
170-199-XXX
Voltage Sensor(s) test failed, cause unknown
1.
Go to the
″
Undetermined problems
″
section
2.
Flash the system and re-test
3.
Replace component under function test
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage limit error
1.
Power supply
2.
System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator Module
error
1.
Voltage Regulator Module (VRM)
2.
Microprocessor
3.
System board
175-000-XXX
Thermal Sensor(s) Test Passed
1.
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2.
System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
1.
Information
2.
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to
″
Undetermined problems
″
section
54
Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer
Summary of Contents for A40 TYPE 6840
Page 1: ...Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271 IBM NetVista Computer...
Page 2: ......
Page 3: ...Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271 IBM NetVista Computer...
Page 41: ...4 Remove the power supply Chapter 5 FRU Replacements 35...
Page 113: ...Chapter 10 Related Service Information 107...
Page 115: ...Chapter 10 Related Service Information 109...
Page 125: ...Chapter 10 Related Service Information 119...
Page 127: ...Chapter 10 Related Service Information 121...
Page 147: ......
Page 148: ...Part Number 06P1775 Printed in USA 1P P N 06P1775...