15.
Press
T
to toggle between the Concurrent Device Remove panels.
16.
Type
1
(Select) next to the location for this drive (0:0:5:0 or 0/00-0E-02).
The Verify Device Concurrent Remove display is shown. The service indicator flashes for that drive
slot.
Choose from the following options:
v
If you are removing a drive from a system or expansion unit, proceed to “Removing the disk drive or
solid-state drive from the 8248-L4T, 8408-E8D, or 9109-RMD system or expansion unit.”
v
If you are removing a drive from the EDR1 PCIe storage enclosure, proceed to “Removing a solid-state
drive from the EDR1 PCIe storage enclosure” on page 39.
Removing the disk drive or solid-state drive from the 8248-L4T,
8408-E8D, or 9109-RMD system or expansion unit
Complete the following steps to remove a disk drive or solid-state drive from a system or from an
expansion unit:
1.
Unlock the drive handle by squeezing it and pulling it out toward you, as shown in Figure 24 on
page 39.
2.
On the Verify Device Concurrent Remove display, verify that the selected drive is the drive you want
to replace, then press Enter.
Note:
Ensure that the drive is not in use to prevent loss of data.
3.
When the identify LED flashes, squeeze and pull the handle of the drive out toward you before you
remove the disk drive or solid-state drive. If the handle is not all the way out, the disk drive or
solid-state drive cannot slide out of the system or out of the expansion unit.
Concurrent Device Remove
Choose a single location for remove operations
1=Select
OPT Name
SCSI Host/Resource Path
Vendor
Product ID
Status
--- ------ ---------------------------- -------- ---------------- --------------
0/00-0E-00
Empty
sg0
0/00-0E-01
IBM
SG9XCA2E200GEIBM
Active
sg5
0/00-0E-02
IBM
SG9XCA2E200GEIBM
Failed
sg3
0/00-0E-03
IBM
SG9XCA2E200GEIBM
Active
sg6
0/00-0E-04
IBM
SG9XCA2E200GEIBM
Active
0/00-0E-05
Empty
0/00-0E-06
Empty
0/00-0E-07
Empty
0/00-0E-08
Empty
sg4
0/00-0E-09
IBM
SG9XCA2E200GEIBM
Active
sg1
0/00-0E-0A
IBM
SG9XCA2E200GEIBM
Active
sg2
0/00-0E-0B
IBM
SG9XCA2E200GEIBM
Active
e=Exit
q=Cancel
t=Toggle
Figure 23. Example Concurrent Device Remove display
38
Disk drives or solid-state drives
Summary of Contents for 8248-L4T
Page 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 2: ......
Page 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 10: ...viii Disk drives or solid state drives...
Page 18: ...2 Disk drives or solid state drives...
Page 70: ...54 Disk drives or solid state drives...
Page 90: ...74 Disk drives or solid state drives...
Page 94: ...78 Disk drives or solid state drives...
Page 98: ...82 Disk drives or solid state drives...
Page 142: ...126 Disk drives or solid state drives...
Page 144: ...128 Disk drives or solid state drives...
Page 148: ...132 Disk drives or solid state drives...
Page 158: ...142 Disk drives or solid state drives...
Page 162: ...146 Disk drives or solid state drives...
Page 198: ...182 Disk drives or solid state drives...
Page 202: ...186 Disk drives or solid state drives...
Page 212: ...196 Disk drives or solid state drives...
Page 213: ......
Page 214: ...Printed in USA...