2.
Prepare to remove the disk drive or solid-state drive from the system or an expansion unit as
described in “Preparing to remove a disk drive or solid-state drive from a system or an expansion
unit controlled by AIX” on page 97.
Proceed to the procedure for removing a disk drive or solid-state drive by using the diagnostic command
Preparing to remove a disk drive or solid-state drive by using the
diagnostic command
Complete the following steps before removing a disk drive or solid-state drive from a system or from an
expansion unit:
1.
If you are removing a solid-state device located on a PCIe RAID and SSD SAS adapter, go to
Removing and replacing the PCIe RAID and SSD SAS adapter, and complete that procedure.
2.
Log in as root user.
3.
At the command line, type
diag
and press Enter.
4.
On the Diagnostic Operating Instructions display, press Enter to continue.
5.
On the Function Selection display, select
Task Selection
.
6.
Select
RAID Array Manager
.
7.
Depending on the adapter that your drive is attached to, select
IBM SAS Disk Array Manager
,
PCI
SCSI Disk Array Manager
, or
PCI-X SCSI Disk Array Manager
.
8.
Select
Diagnostics and Recovery Options
.
9.
Select
SCSI and SCSI RAID Hot Plug Manager
.
10.
To identify the location of the drive to be removed, select
Identify a Device Attached to an SCSI
Hot Swap Enclosure Device
.
11.
Choose the slot corresponding to the disk and press Enter. The identify LED for that slot will flash
rapidly.
12.
Verify that the identify LED for that slot is flashing rapidly, and record the location of the slot.
13.
Press Enter to stop the LED from flashing and continue.
14.
To prepare to remove the drive, press F3 to return to the SCSI and SCSI RAID Hot Plug Manager
display.
Choose from the following options:
v
If you are removing a drive from a system or expansion unit, proceed to “Removing the disk drive or
solid-state drive from the 8248-L4T, 8408-E8D, or 9109-RMD system or expansion unit.”
v
If you are removing a drive from the EDR1 PCIe storage enclosure, proceed to “Removing a solid-state
drive from the EDR1 PCIe storage enclosure” on page 31.
Removing the disk drive or solid-state drive from the 8248-L4T,
8408-E8D, or 9109-RMD system or expansion unit
Complete the following steps to remove a disk drive or solid-state drive from a system or from an
expansion unit:
1.
Select
Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device
.
2.
Select the drive that you want to remove and press Enter. To view the locations of the service
indicators, see “Disk drives or solid-state drives locations and service indicators” on page 89.
3.
When the identify LED turns on solid, unlock the drive handle by squeezing it and pulling it out
toward you, as shown in Figure 17 on page 31. If the handle is not all the way out, the disk drive or
solid-state drive cannot slide out of the system or out of the expansion unit.
4.
Support the bottom of the drive as you slide it out of the system or an expansion unit. Do not hold
the disk drive or solid-state drive by the handle.
5.
Press Enter on the console to indicate that you have removed the drive. The identify LED turns off.
30
Disk drives or solid-state drives
Summary of Contents for 8248-L4T
Page 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 2: ......
Page 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 10: ...viii Disk drives or solid state drives...
Page 18: ...2 Disk drives or solid state drives...
Page 70: ...54 Disk drives or solid state drives...
Page 90: ...74 Disk drives or solid state drives...
Page 94: ...78 Disk drives or solid state drives...
Page 98: ...82 Disk drives or solid state drives...
Page 142: ...126 Disk drives or solid state drives...
Page 144: ...128 Disk drives or solid state drives...
Page 148: ...132 Disk drives or solid state drives...
Page 158: ...142 Disk drives or solid state drives...
Page 162: ...146 Disk drives or solid state drives...
Page 198: ...182 Disk drives or solid state drives...
Page 202: ...186 Disk drives or solid state drives...
Page 212: ...196 Disk drives or solid state drives...
Page 213: ......
Page 214: ...Printed in USA...